Technical Specifications
Date Printed: 11/6/2015
STEPS TO BE TAKEN IF MATERIAL IS RELEASED OR SPILLED: Contain spilled liquid with sand or earth. DO NOT use
combustible materials such as sawdust. Isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Eliminate all ignition sources; use explosion-proof equipment. Place material in a container and dispose of according to local,
provincial, state and federal regulations. Remove all sources of ignition, ventilate area and remove with inert absorbent and non-
sparking tools. Dispose of according to local, state (provincial) and federal regulations. Do not incinerate closed containers.
Ventilate area, isolate spilled material, and remove with inert absorbent. Dispose of contaminated absorbent, container, and unused
contents in accordance with local, state, and federal regulations.
7. Handling and Storage
HANDLING: Wash thoroughly after handling. Wash hands before eating. Remove contaminated clothing and launder before reuse.
Use only with adequate ventilation. Follow all MSDS/label precautions even after container is emptied because it may retain product
residues. Avoid breathing fumes, vapors, or mist. Avoid contact with eyes, skin and clothing.
STORAGE: Store in a dry, well ventilated place. Keep container tightly closed when not in use. Keep containers tightly closed.
Isolate from heat, electrical equipment, sparks and open flame. Do not store above 120 ° F. Store large quantities in buildings
designed and protected for storage of NFPA Class II combustible liquids. Keep away from heat, sparks, flame and sources of
ignition. Keep container closed when not in use. Avoid excess heat. Product should be stored in tightly sealed containers and
protected from heat, moisture, and foreign materials.
8. Exposure Controls/Personal Protection
Chemical Name CAS-No.
Weight %
Less Than
ACGIH TLV-
TWA
ACGIH TLV-
STEL
OSHA PEL-TWA
OSHA PEL-
CEILING
Acetone 67-64-1 70.0 250 ppm 500 ppm 1000 ppm N.E.
Toluene 108-88-3 25.0 20 ppm N.E. 200 ppm 300 ppm
Methanol 67-56-1 10.0 200 ppm 250 ppm 200 ppm N.E.
PERSONAL PROTECTION
ENGINEERING CONTROLS: Use process enclosures, local exhaust ventilation, or other engineering controls to control airborne
levels below recommended exposure limits. Use explosion-proof ventilation equipment. Provide general dilution of local exhaust
ventilation in volume and pattern to keep TLV of hazardous ingredients below acceptable limits. Prevent build-up of vapors by
opening all doors and windows to achieve cross-ventilation.
RESPIRATORY PROTECTION: A respiratory protection program that meets OSHA 1910.134 and ANSI Z88.2 requirements must be
followed whenever workplace conditions warrant a respirator's use. A NIOSH/MSHA approved air purifying respirator with organic
vapor cartridge or canister may be permissible under certain circumstances where airborne concentrations are expected to exceed
exposure limits.
SKIN PROTECTION: Use gloves to prevent prolonged skin contact. Use impervious gloves to prevent skin contact and absorption of
this material through the skin. Nitrile or Neoprene gloves may afford adequate skin protection.
EYE PROTECTION: Use safety eyewear designed to protect against splash of liquids.
OTHER PROTECTIVE EQUIPMENT: Refer to safety supervisor or industrial hygienist for further guidance regarding types of
personal protective equipment and their applications. Refer to safety supervisor or industrial hygienist for further information
regarding personal protective equipment and its application.
HYGIENIC PRACTICES: Wash thoroughly with soap and water before eating, drinking or smoking. Remove contaminated clothing
immediately and launder before reuse.
9. Physical and Chemical Properties
Appearance:
Liquid
Physical State:
Liquid
Odor:
Solvent Like
Odor Threshold:
N.E.
Relative Density:
0.808
pH:
N.A.
Freeze Point, °C:
N.D.
Viscosity:
N.D.
Solubility in Water:
Slight
Partition Coefficient, n-octanol/
water:
N.D.
Decompostion Temp., °C:
N.D.
Boiling Range, °C:
56 - 111
Explosive Limits, vol%:
1.2 - 36.0
Flammability:
Supports Combustion
Flash Point, °C:
-20
Evaporation Rate:
Slower than Ether
Auto-ignition Temp., °C:
N.D.
Vapor Density:
Heavier than Air
Vapor Pressure:
N.D.
(See "Other information" Section for abbreviation legend)
Page 3 / 5