Technical Specifications
Date Printed: 5/15/2015
FIRST AID - INHALATION: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.
Get immediate medical attention. Do NOT use mouth-to-mouth resuscitation. If you experience difficulty in breathing, leave the
area to obtain fresh air. If continued difficulty is experienced, get medical assistance immediately.
FIRST AID - INGESTION: Aspiration hazard: Do not induce vomiting or give anything by mouth because this material can enter the
lungs and cause severe lung damage. Get immediate medical attention. If swallowed, get medical attention.
5. Fire-fighting Measures
EXTINGUISHING MEDIA:
Alcohol Film Forming Foam, Carbon Dioxide, Dry Chemical, Dry Sand, Water Fog
UNUSUAL FIRE AND EXPLOSION HAZARDS: No unusual fire or explosion hazards noted. Closed containers may explode when
exposed to extreme heat due to buildup of steam. Keep containers tightly closed. Isolate from heat, electrical equipment, sparks
and open flame.
SPECIAL FIREFIGHTING PROCEDURES: Water may be used to cool closed containers to prevent pressure buildup and possible
autoignition or explosion. Evacuate area and fight fire from a safe distance. Use water spray to keep fire-exposed containers cool.
Containers may explode when heated.
6. Accidental Release Measures
STEPS TO BE TAKEN IF MATERIAL IS RELEASED OR SPILLED: Remove all sources of ignition, ventilate area and remove
with inert absorbent and non-sparking tools. Dispose of according to local, state (provincial) and federal regulations. Do not
incinerate closed containers. Ventilate area, isolate spilled material, and remove with inert absorbent. Dispose of contaminated
absorbent, container, and unused contents in accordance with local, state, and federal regulations.
7. Handling and Storage
HANDLING: Wash thoroughly after handling. Wash hands before eating. Remove contaminated clothing and launder before reuse.
Use only with adequate ventilation. Follow all MSDS/label precautions even after container is emptied because it may retain product
residues. Avoid breathing fumes, vapors, or mist. Avoid contact with eyes, skin and clothing.
STORAGE: Product should be stored in tightly sealed containers and protected from heat, moisture, and foreign materials. Store in
a dry, well ventilated place. Keep container tightly closed when not in use. Keep containers tightly closed. Isolate from heat,
electrical equipment, sparks and open flame. Keep away from heat, sparks, flame and sources of ignition. Avoid excess heat. Do
not store above 120 ° F. Store large quantities in buildings designed and protected for storage of NFPA Class II combustible liquids.
8. Exposure Controls/Personal Protection
Chemical Name CAS-No.
Weight %
Less Than
ACGIH TLV-
TWA
ACGIH TLV-
STEL
OSHA PEL-TWA
OSHA PEL-
CEILING
Titanium Dioxide 13463-67-7 30.0
10 mg/m3 (Total
Dust)
N.E.
15 mg/m3 [Total
Dust]
N.E.
Xylene (mixed isomers) 1330-20-7 15.0 100 ppm 150 ppm 100 ppm N.E.
Propylene Glycol Monomethyl
Ether
107-98-2 10.0 50 ppm 100 ppm N.E. N.E.
Solvent Naphtha, Light Aromatic 64742-95-6 10.0 N.E. N.E. N.E. N.E.
1,2,4-Trimethylbenzene 95-63-6 5.0
25 ppm (NIOSH
REL)
N.E. N.E. N.E.
Ethylbenzene 100-41-4 5.0 20 ppm 125 ppm 100 ppm N.E.
1,3,5-Trimethylbenzene 108-67-8 5.0 25 ppm N.E. N.E. N.E.
PERSONAL PROTECTION
ENGINEERING CONTROLS: Use process enclosures, local exhaust ventilation, or other engineering controls to control airborne
levels below recommended exposure limits. Prevent build-up of vapors by opening all doors and windows to achieve cross-
ventilation.
RESPIRATORY PROTECTION: A respiratory protection program that meets OSHA 1910.134 and ANSI Z88.2 requirements must
be followed whenever workplace conditions warrant a respirator's use. A NIOSH/MSHA approved air purifying respirator with an
organic vapor cartridge or canister may be permissible under certain circumstances where airborne concentrations are expected to
exceed exposure limits.
Protection provided by air purifying respirators is limited. Use a positive pressure air supplied respirator if there is any potential for
an uncontrolled release, exposure levels are not known, or in any other circumstances where air purifying respirators may not
provide adequate protection.
SKIN PROTECTION: Use gloves to prevent prolonged skin contact. Nitrile or Neoprene gloves may afford adequate skin
protection.