CLEAN-UP
Wipe off tip before storing. Clean-up wet paint with xylene or
mineral spirits. Properly discard empty container. Do not burn
or place in trash compactor. Empty container can be recycled.
.PRODUCT APPLICATION (cont.) .
CLOGGING
If the valve clogs, twist and pull off spray tip and rinse in a
solvent such as mineral spirits. Do not insert any object into
can valve opening.
. PHYSICAL PROPERTIES .
FLAT ENAMELS &
PRIMERS
GLOSS FINISHES
GALVANIZING*
Resin Type
Modified Alkyd
Modified Alkyd
Epoxy Ester
Pigment Type
Varies with color
Varies with color
1685830 contains 93% zinc in
the dry film
244305 contains greater than
65% zinc in the dry film (also
contains aluminum)
Solvents
Acetone, xylene, toluene (fluorescents contain hexane) and liquefied petroleum gas propellant
MIR
Maximum value of 1.2
Finishes: Max. value of 1.4
Metallics: Max. value of 1.9
Maximum value of 1.2
Fill Weight
12 oz.
Finishes: 12 oz.
Metallics: 11 oz.
14 oz.
Recommended Dry Film Thickness
Per Coat
1-2 mils
(25-50µ)
1-2 mils
(25-50µ)
1-2 mils
(25-50µ)
Practical Coverage at
Recommended DFT
12-15 sq.ft./can
(1.1-1.4 m
2
/can)
12-15 sq.ft./can
(1.1-1.4 m
2
/can)
12-15 sq.ft./can
(1.1-1.4 m
2
/can)
Dry Times at 70-80°F
(21-27°C) and 50%
Relative Humidity
Touch
10 minutes
10 minutes
10-20 minutes
Handle
1 hour
1 hour
1-2 hours
Recoat
Within 1 hour or after 24
hours
Within 1 hour or after 24
hours
Within 1 hour or after 24
hours
Dry Heat Resistance
200°F (93°C)**
200°F (93°C)**
200°F (93°C)**
Shelf Life
5 years
5 years
5 years
Safety Information
For additional information, see MSDS
Calculated values are shown and may vary slightly from the actual manufactured material.
*Do not topcoat galvanizing compounds with an alkyd finish.
**Some discoloration may occur at temperatures above 150°F (65°C).
Actual coverage with complete hiding. Coverage may vary with color and substrate. The coverage rate can be optimized if applied
over the white or gray primer.