Use and Care Manual
TECHNICAL DATA 
  COUNTERTOP TRANSFORMATIONS
TM 
  Rust-Oleum Corporation    Form: GDH-64
  11 Hawthorn Parkway   Phone: 877•385•8155  Rev.: 052013 
  Vernon Hills, Illinois 60061  www.rustoleum.com 
  An RPM Company 
.PHYSICAL PROPERTIES                                                                                                  . 
BASE COAT 
WETTING AGENT 
TOP COAT 
Resin Type 
Acrylic 
Surfactant 
Modified silicone epoxy 
Pigment Type 
Various 
n/a 
Clear 
Solvents 
Water 
Water 
n/a 
Weight 
Per Gallon 
8.6-9.1 lbs. 
8.4 lbs. 
9.0 lbs. 
Per Liter 
1.0-1.1 kg 
1.0 kg 
1.0 kg 
Solids 
By Weight 
33.5-36.0% 
1.5% 
98% 
By Volume 
30.0-33.0% 
1.0% 
97% 
Volatile Organic Compounds 
(activated material) 
<250 g/l (2.08 lbs./gal.) 
<250 g/l (2.08 lbs./gal.) 
<250 g/l (2.08 lbs./gal.) 
Recommended Dry Film 
(DFT) Per Coat 
2.0-2.5 mils (50-62.5µ) 
n/a 
4.0-8.0 mils (100-200µ) 
Wet Film to Achieve DFT (unthinned 
material) 
6.0-7.5 mils (150-187.5µ) 
n/a 
4.0-8.0 mils (100-200µ) 
Theoretical Coverage at 
1 mil DFT (25µ) 
480-530 sq. ft./gal. 
(11.8-13.0 m
2
/l) 
n/a 
1,550 sq. ft./gal. 
(38 m
2
/l) 
Practical Coverage at Recommended 
DFT (assumes 15% material loss) 
160-200 sq. ft./gal. 
(3.9-4.7 m
2
/l) 
n/a 
165-330 sq. ft./gal. 
(4.0-8.1 m
2
/l) 
Dry Times at 70-80°F 
(21-27°C) and 50% 
rel. hum. 
Touch 
Minimum 12 hours 
n/a 
n/a 
Recoat 
n/a 
n/a 
4-8 hours 
Stain Sealing 
n/a 
n/a 
2 days 
Full 
Hardness 
n/a 
n/a 
7-10 days 
Dry Heat Resistance 
200°F (93°C) 
n/a 
200°F (93°C) 
Shelf Life 
2 years 
n/a 
2 years 
Flash Point 
>210°F (99°C) 
n/a 
>160°F (67°C) 
Safety Information 
COMBUSTIBLE LIQUID AND VAPOR. HARMFUL IF INHALED. MAY AFFECT 
BRAIN OR NERVOUS SYSTEM CAUSING DIZZINESS, HEADACHE OR NAUSEA. 
CAUSES RESPIRATORY TRACT, EYE AND SKIN IRRITATION. FOR 
INDUSTRIAL OR COMMERCIAL USE ONLY. KEEP OUT OF REACH OF 
CHILDREN.SEE THE PRODUCT MATERIAL SAFETY DATA SHEET (MSDS) 
AND LABEL WARNINGS FOR ADDITIONAL SAFETY INFORMATION. 
Safety Information 
For additional information, see MSDS 
The  technical  data  and  suggestions  for  use  contained  herein  are  correct  to  the  best  of  our  knowledge,  and  offered  in  good  faith. The 
statements of this literature do not constitute a warranty, express, or implied, as to the performance of these products. As conditions and use 
of our materials are beyond our control, we can guarantee these products only to conform to our standards of quality, and our liability, if any, 
will be limited to replacement of defective materials. All technical information is subject to change without notice.