SDS
Table Of Contents
Date Printed: 8/24/2022
ENGINEERING CONTROLS: Use process enclosures, local exhaust ventilation, or other engineering controls to control airborne 
levels below recommended exposure limits. Use explosion-proof ventilation equipment. Provide general dilution of local exhaust 
ventilation in volume and pattern to keep TLV of hazardous ingredients below acceptable limits. Prevent build-up of vapors by 
opening all doors and windows to achieve cross-ventilation.
RESPIRATORY PROTECTION: A respiratory protection program that meets OSHA 1910.134 and ANSI Z88.2 requirements must be 
followed whenever workplace conditions warrant a respirator's use. A NIOSH/MSHA approved air purifying respirator with organic 
vapor cartridge or canister may be permissible under certain circumstances where airborne concentrations are expected to exceed 
exposure limits.
SKIN PROTECTION: Use gloves to prevent prolonged skin contact. Nitrile or Neoprene gloves may afford adequate skin protection.
EYE PROTECTION: Use safety eyewear designed to protect against splash of liquids.
OTHER PROTECTIVE EQUIPMENT: Refer to safety supervisor or industrial hygienist for further guidance regarding types of 
personal protective equipment and their applications.
HYGIENIC PRACTICES: Wash thoroughly with soap and water before eating, drinking or smoking. Remove contaminated clothing 
immediately and launder before reuse.
Engineering Measures for Combustible Dust: No Information
9. Physical and Chemical Properties
Appearance:
Aerosolized Mist
Physical State:
Liquid
Odor:
Solvent Like N.E.
Odor Threshold:
Specific Gravity:
0.804
pH:
N.A.
Freeze Point, °C:
N.D.
Viscosity:
N.D.
Solubility in Water:
Slight
Partition Coefficient, n-octanol/
water:
N.D.
Decomposition Temp., °C:
N.D.
Boiling Range, °C:
-37 - 537
Explosive Limits, vol%:
0.9 - 13.0
Flammability:
Supports Combustion -96
Flash Point, °C:
Evaporation Rate:
Slower than Ether
Auto-Ignition Temp., °C:
N.D.
Vapor Density:
Heavier than Air
Vapor Pressure:
N.D.
(See "Other information" Section for abbreviation legend)
10. Stability and Reactivity
Conditions to Avoid: Avoid temperatures above 120°F (49°C). Avoid all possible sources of ignition.
Incompatibility: Incompatible with strong oxidizing agents, strong acids and strong alkalies.
Hazardous Decomposition: By open flame, carbon monoxide and carbon dioxide. When heated to decomposition, it emits acrid 
smoke and irritating fumes. Contains solvents which may form carbon monoxide, carbon dioxide, and formaldehyde.
Hazardous Polymerization: Will not occur under normal conditions.
Stability: This product is stable under normal storage conditions.
11. Toxicological Information
EFFECTS OF OVEREXPOSURE - EYE CONTACT: Causes Serious Eye Irritation
EFFECTS OF OVEREXPOSURE - SKIN CONTACT: No Information
EFFECTS OF OVEREXPOSURE - INHALATION: Harmful if inhaled. High gas, vapor, mist or dust concentrations may be harmful if 
inhaled.  Avoid breathing fumes, spray, vapors, or mist. High vapor concentrations are irritating to the eyes, nose, throat and lungs. 
Prolonged or excessive inhalation may cause respiratory tract irritation.
EFFECTS OF OVEREXPOSURE - INGESTION: Harmful if swallowed.
EFFECTS OF OVEREXPOSURE - CHRONIC HAZARDS: May cause central nervous system disorder (e.g., narcosis involving a 
loss of coordination, weakness, fatigue, mental confusion, and blurred vision) and/or damage. High concentrations may lead to 
central nervous system effects (drowsiness, dizziness, nausea, headaches, paralysis, and blurred vision) and/or damage. Reports 
have associated repeated and prolonged occupational overexposure to solvents with permanent brain and nervous system damage. 
Overexposure to xylene in laboratory animals has been associated with liver abnormalities, kidney, lung, spleen, eye and blood 
damage as well as reproductive disorders. Effects in humans, due to chronic overexposure, have included liver, cardiac 
abnormalities and nervous system damage. Contains carbon black. Chronic inflammation, lung fibrosis, and lung tumors have been 
observed in some rats experimentally exposed for long periods of time to excessive concentrations of carbon black and several
insoluble fine dust particles. Tumors have not been observed in other animal species (i.e., mouse and hamster) under similar
circumstances and study conditions. Epidemiological studies of North American workers show no evidence of clinically significant 
adverse health effects due to occupational exposure to carbon black.
No Information
Page 4 / 6