MSDS
Date Printed: 5/18/2015
FIRST AID - INHALATION: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.
Get immediate medical attention. Do NOT use mouth-to-mouth resuscitation. If you experience difficulty in breathing, leave the
area to obtain fresh air. If continued difficulty is experienced, get medical assistance immediately.
FIRST AID - INGESTION: Aspiration hazard: Do not induce vomiting or give anything by mouth because this material can enter the
lungs and cause severe lung damage. Get immediate medical attention. If swallowed, get medical attention.
5. Fire-fighting Measures
EXTINGUISHING MEDIA:
Alcohol Film Forming Foam, Carbon Dioxide, Dry Chemical, Dry Sand, Water Fog
UNUSUAL FIRE AND EXPLOSION HAZARDS: FLASH POINT IS LESS THAN 20°F. EXTREMELY FLAMMABLE LIQUID AND
VAPOR!Water spray may be ineffective. Closed containers may explode when exposed to extreme heat due to buildup of steam.
Closed containers may explode when exposed to extreme heat. Vapors may form explosive mixtures with air. Vapors can travel to
a source of ignition and flash back. Isolate from heat, electrical equipment, sparks and open flame. Perforation of the pressurized
container may cause bursting of the can. No unusual fire or explosion hazards noted. Keep containers tightly closed.
SPECIAL FIREFIGHTING PROCEDURES: Full protective equipment including self-contained breathing apparatus should be used.
Evacuate area and fight fire from a safe distance. Water may be used to cool closed containers to prevent pressure buildup and
possible autoignition or explosion. Use water spray to keep fire-exposed containers cool. Containers may explode when heated.
6. Accidental Release Measures
STEPS TO BE TAKEN IF MATERIAL IS RELEASED OR SPILLED: Contain spilled liquid with sand or earth. DO NOT use
combustible materials such as sawdust. Isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Remove all sources of ignition, ventilate area and remove with inert absorbent and non-sparking tools. Dispose of according to
local, state (provincial) and federal regulations. Do not incinerate closed containers. Ventilate area, isolate spilled material, and
remove with inert absorbent. Dispose of contaminated absorbent, container, and unused contents in accordance with local, state,
and federal regulations.
7. Handling and Storage
HANDLING: Wash thoroughly after handling. Wash hands before eating. Remove contaminated clothing and launder before reuse.
Use only with adequate ventilation. Follow all MSDS/label precautions even after container is emptied because it may retain product
residues. Avoid breathing fumes, vapors, or mist. Avoid contact with eyes, skin and clothing.
STORAGE: Keep containers tightly closed. Isolate from heat, electrical equipment, sparks and open flame. Contents under
pressure. Do not store above 120 ° F. Store large quantities in buildings designed and protected for storage of NFPA Class I
flammable liquids. Product should be stored in tightly sealed containers and protected from heat, moisture, and foreign materials.
Store in a dry, well ventilated place. Keep container tightly closed when not in use. Keep away from heat, sparks, flame and sources
of ignition. Avoid excess heat.
8. Exposure Controls/Personal Protection
Chemical Name CAS-No.
Weight %
Less Than
ACGIH TLV-
TWA
ACGIH TLV-
STEL
OSHA PEL-TWA
OSHA PEL-
CEILING
Acetone 67-64-1 35.0 500 ppm 750 ppm 1000 ppm N.E.
Medium Oil Alkyd Proprietary 20.0 N.E. N.E. N.E. N.E.
Propane 74-98-6 20.0 1000 ppm N.E. 1000 ppm N.E.
Xylene (mixed isomers) 1330-20-7 10.0 100 ppm 150 ppm 100 ppm N.E.
n-Butane 106-97-8 10.0 1000 ppm 1000 ppm N.E. N.E.
n-Butyl Acetate 123-86-4 10.0 150 ppm 200 ppm 150 ppm N.E.
Ethylbenzene 100-41-4 5.0 20 ppm 125 ppm 100 ppm N.E.
Propylene Glycol Monobutyl
Ether
5131-66-8 5.0 N.E. N.E. N.E. N.E.
Titanium Dioxide 13463-67-7 1.0
10 mg/m3 (Total
Dust)
N.E.
15 mg/m3 [Total
Dust]
N.E.
PERSONAL PROTECTION
ENGINEERING CONTROLS: Use explosion-proof ventilation equipment. Provide general dilution of local exhaust ventilation in
volume and pattern to keep TLV of hazardous ingredients below acceptable limits. Prevent build-up of vapors by opening all doors
and windows to achieve cross-ventilation. Use process enclosures, local exhaust ventilation, or other engineering controls to control
airborne levels below recommended exposure limits.
Page 3 / 7