MSDS

Date Printed: 11/18/2013
1-Chloro-4(Trifluoromethyl)
Benzene
98-56-6 20.0 N.E. N.E. N.E. N.E.
Talc 14807-96-6 5.0 2 mg/m3 N.E.
0.1 mg/m3
[Respirable]
N.E.
Mineral Spirits 64742-88-7 5.0 100 ppm N.E. 100 ppm N.E.
Carbon Black 1333-86-4 1.0 3 mg/m3 N.E. 3.5 mg/m3 N.E.
Crystalline Silica 14808-60-7 1.0
0.025 mg/m3
[Respirable]
N.E.
0.1 mg/m3
[Respirable]
N.E.
4. First-aid Measures4. First-aid Measures
4. First-aid Measures4. First-aid Measures
FIRST AID FIRST AID
FIRST AID FIRST AID
--
--
EYE CONTACT: EYE CONTACT:
EYE CONTACT: EYE CONTACT:
Immediately flush eyes with plenty of water for at least 15 minutes holding eyelids open. Get medical
attention. Do NOT allow rubbing of eyes or keeping eyes closed.
FIRST AID FIRST AID
FIRST AID FIRST AID
--
--
SKIN CONTACT: SKIN CONTACT:
SKIN CONTACT: SKIN CONTACT:
Wash skin with soap and water. Remove contaminated clothing. Get medical attention if irritation
develops or persists.
FIRST AID FIRST AID
FIRST AID FIRST AID
--
--
INHALATION: INHALATION:
INHALATION: INHALATION:
Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get
immediate medical attention. Do NOT use mouth-to-mouth resuscitation. If you experience difficulty in breathing, leave the area to
obtain fresh air. If continued difficulty is experienced, get medical assistance immediately.
FIRST AID FIRST AID
FIRST AID FIRST AID
--
--
INGESTION: INGESTION:
INGESTION: INGESTION:
Aspiration hazard: Do not induce vomiting or give anything by mouth because this material can enter the
lungs and cause severe lung damage. Get immediate medical attention. If swallowed, get medical attention.
5. Fire-fighting Measures5. Fire-fighting Measures
5. Fire-fighting Measures5. Fire-fighting Measures
Flash Point, °F 90 (Setaflash)
Extinguishing Media: Dry Chemical, Dry Sand, Water Fog
UNUSUAL FIRE AND EXPLOSION HAZARDS: Keep containers tightly closed. No unusual fire or explosion hazards noted. Closed
containers may explode when exposed to extreme heat due to buildup of steam. Isolate from heat, electrical equipment, sparks and
open flame.
SPECIAL FIREFIGHTING PROCEDURES: Water may be used to cool closed containers to prevent pressure buildup and possible
autoignition or explosion. Evacuate area and fight fire from a safe distance. Use water spray to keep fire-exposed containers cool.
Containers may explode when heated.
6. Accidental Release Measures
STEPS TO BE TAKEN IF MATERIAL IS RELEASED OR SPILLED: Contain spilled liquid with sand or earth. DO NOT use
combustible materials such as sawdust. Dispose of according to local, state (provincial) and federal regulations. Do not incinerate
closed containers. Remove all sources of ignition, ventilate area and remove with inert absorbent and non-sparking tools. Ventilate
area, isolate spilled material, and remove with inert absorbent. Dispose of contaminated absorbent, container, and unused contents
in accordance with local, state, and federal regulations.
7. Handling and Storage
HANDLING: Wash thoroughly after handling. Wash hands before eating. Follow all MSDS/label precautions even after container is
emptied because it may retain product residues. Avoid breathing fumes, vapors, or mist. Avoid contact with eyes. Remove
contaminated clothing and launder before reuse. Use only with adequate ventilation. Avoid contact with eyes, skin and clothing.
STORAGE: Keep containers tightly closed. Isolate from heat, electrical equipment, sparks and open flame. Keep away from heat,
sparks, flame and sources of ignition. Keep container closed when not in use. Product should be stored in tightly sealed containers
and protected from heat, moisture, and foreign materials. Store in a dry, well ventilated place. Keep container tightly closed when not
in use. Contents under pressure. Do not store above 120 ° F. Store large quantities in buildings designed and protected for storage
of NFPA Class I flammable liquids. Avoid excess heat.
8. Exposure Controls/Personal Protection
ENGINEERING CONTROLS: Use process enclosures, local exhaust ventilation, or other engineering controls to control airborne
levels below recommended exposure limits. Prevent build-up of vapors by opening all doors and windows to achieve cross-
ventilation.
Page 2 / 5