MSDS

Date Printed: 11/19/2014
OTHER PROTECTIVE EQUIPMENT: Refer to safety supervisor or industrial hygienist for further guidance regarding types of
personal protective equipment and their applications.
HYGIENIC PRACTICES: Wash thoroughly with soap and water before eating, drinking or smoking. Remove contaminated clothing
immediately and launder before reuse.
9. Physical and Chemical Properties
Vapor Density Heavier than Air Odor: Solvent Like
Appearance: Aerosolized Mist Evaporation Rate: Faster than Ether
Solubility in Water: Negligible Freeze Point: N.D.
Specific Gravity: 0.726 pH: N.A.
Physical State: Liquid
(See section 16 for abbreviation legend)
10. Stability and Reactivity
CONDITIONS TO AVOID: Avoid temperatures above 120 ° F. Avoid contact with strong acid and strong bases. Avoid all possible
sources of ignition.
INCOMPATIBILITY: Incompatible with strong oxidizing agents, strong acids and strong alkalies.
HAZARDOUS DECOMPOSITION: Contains solvents which may form carbon monoxide, carbon dioxide, and formaldehyde. By open
flame, carbon monoxide and carbon dioxide. When heated to decomposition, it emits acrid smoke and irritating fumes.
HAZARDOUS POLYMERIZATION: Will not occur under normal conditions.
STABILITY: May form peroxides of unkown stability. This product is stable under normal storage conditions.
11. Toxicological Information
Chemical Name LD50 LC50
Liquefied Petroleum Gas N.E. N.E.
Aliphatic Hydrocarbon 5000 mg/kg (Rat, Oral) N.E.
n-Butyl Acetate 13100 mg/kg (Rat, Oral) 2000 ppm (Rat, Inhalation, 4Hr)
Methyl Isobutyl Ketone 2080 mg/kg (Oral, Rat) 8.2 mg/L (Inhalation, Rat, 4 hr)
Methyl Acetate >5000 mg/kg (Oral, Rat) 16000 ppm (Inhalation, Rat, 4 hr)
Mineral Spirits >5000 mg/kg (Rat, Oral) >5.28 mg/L( Rat, Inhalation, 4 hr)
Ethyl Acetate 5620 mg/kg (Rat, Oral) 1600 ppm (Rat, Inhalation, 8Hr)
Ethylbenzene 3500 mg/kg (Rat, Oral) 17.2 mg/kg (Inhalation, Rat, 4 hr)
12. Ecological Information
ECOLOGICAL INFORMATION: Product is a mixture of listed components.
13. Disposal Information
DISPOSAL INFORMATION: Dispose of material in accordance to local, state, and federal regulations and ordinances. Do not allow
to enter waterways, wastewater, soil, storm drains or sewer systems.
Page 3 / 5