Use and Care Manual
EPOXYSHIELD
®
LOW VOC PREMIUM CLEAR COATING
TECHNICAL DATA
The technical data and suggestions for use contained herein are correct to the best of our knowledge, and offered in good faith. The statements of this literature do not constitute
a warranty, express, or implied, as to the performance of these products. As conditions and use of our materials are beyond our control, we can guarantee these products only
to conform to our standards of quality, and our liability, if any, will be limited to replacement of defective materials. All technical information is subject to change without notice.
Form: 5089790
Rev.: 012312
Rust-Oleum Corporation
11 Hawthorn Parkway
Vernon Hills, Illinois 60061
An RPM Company
Phone: 877
•
385
•
8155
www.rustoleum.com/industrial
®
PHYSICAL PROPERTIES
EPOXYSHIELD LOW VOC PREMIUM CLEAR COATING
Resin Type
Amine cured epoxy
Solvents
Oxsol100, Methyl Acetate
Weight*
Per Gallon
9.0 lbs.
Per Liter
1.1 kg
Solids*
By Weight
87.6%
By Volume
86.5%
Volatile Organic Compounds*
<50 g/l (0.41 lbs./gal.)
Mixing Ratio
2:1 Base to Activator (by volume)
Recommended Dry Film
Thickness (DFT) Per Coat
2.0-5.0 mils (50-125µ)
Wet Film to Achieve DFT
(Unthinned Material)
3.0-7.0 mils (75-175µ)
Theoretical Coverage at
1 mil DFT (25µ)
1,387 sq.ft./gal. (34.1 m
2
/l)
Practical Coverage at Recommended
DFT (assumes 15% material loss)
500 sq.ft./gal. (23 m
2
/l) on painted surfaces
250 sq.ft./gal. (46 m
2
/l) on bare concrete
Induction Period
None
Pot Life @ 70-80°F (21-27°C)
and 50% Rel. Hum.
90 minutes
Dry Times
at 70-80°F
(21-27°C) and
50% Rel. Hum.
Lt. Foot Traffic
10 hours
Hv. Foot Traffic
24 hours
Vehicle Traffic
4 days
Shelf Life
5 years
Safety
Information
Flash Point
Base Component: 44°F (7°C) • Activator Component: 206°F (127°C)
Contains
—
Warning!
FOR ADDITIONAL INFORMATION, SEE MSDS.
Calculated values may vary slightly from the actual manufactured material.
*Activated material.