SDS
Date Printed: 3/10/2023
Yellow Iron Oxide 51274-00-1 5.0 N.E. N.E. N.E. N.E.
Toluene 108-88-3 1.0 20 ppm N.E. 200 ppm 300 ppm
Amorphous Silica 7631-86-9 1.0 N.E. N.E. 50 µg/m3 N.E.
PERSONAL PROTECTION
ENGINEERING CONTROLS: Use process enclosures, local exhaust ventilation, or other engineering controls to control airborne
levels below recommended exposure limits. Prevent build-up of vapors by opening all doors and windows to achieve cross-
ventilation.
RESPIRATORY PROTECTION: A respiratory protection program that meets OSHA 1910.134 and ANSI Z88.2 requirements must be
followed whenever workplace conditions warrant a respirator's use. A NIOSH/MSHA approved air purifying respirator with an organic
vapor cartridge or canister may be permissible under certain circumstances where airborne concentrations are expected to exceed
exposure limits.
Protection provided by air purifying respirators is limited. Use a positive pressure air supplied respirator if there is any potential for an
uncontrolled release, exposure levels are not known, or in any other circumstances where air purifying respirators may not provide
adequate protection.
SKIN PROTECTION: Use gloves to prevent prolonged skin contact. Nitrile or Neoprene gloves may afford adequate skin protection.
EYE PROTECTION: Use safety eyewear designed to protect against splash of liquids.
OTHER PROTECTIVE EQUIPMENT: Refer to safety supervisor or industrial hygienist for further guidance regarding types of
personal protective equipment and their applications.
HYGIENIC PRACTICES: Wash thoroughly with soap and water before eating, drinking or smoking. Remove contaminated clothing
immediately and launder before reuse.
Engineering Measures for Combustible Dust: No Information
9. Physical and Chemical Properties
Appearance:
Liquid
Physical State:
Liquid
Odor:
Solvent Like N.E.
Odor Threshold:
Specific Gravity:
1.375
pH:
N.A.
Freeze Point, °C:
N.D.
Viscosity:
N.D.
Solubility in Water:
Slight
Partition Coefficient, n-octanol/
water:
N.D.
Decomposition Temp., °C:
N.D.
Boiling Range, °C:
117 - 537
Explosive Limits, vol%:
1.0 - 8.0
Flammability:
Supports Combustion 27
Flash Point, °C:
Evaporation Rate:
Slower than Ether
Auto-Ignition Temp., °C:
N.D.
Vapor Density:
Heavier than Air
Vapor Pressure:
N.D.
(See "Other information" Section for abbreviation legend)
10. Stability and Reactivity
Conditions to Avoid: Avoid temperatures above 120°F (49°C). Avoid all possible sources of ignition.
Incompatibility: Incompatible with strong oxidizing agents, strong acids and strong alkalies.
Hazardous Decomposition: By open flame, carbon monoxide and carbon dioxide. When heated to decomposition, it emits acrid
smoke and irritating fumes. Contains solvents which may form carbon monoxide, carbon dioxide, and formaldehyde.
Hazardous Polymerization: Will not occur under normal conditions.
Stability: This product is stable under normal storage conditions. May form peroxides of unknown stability.
11. Toxicological Information
EFFECTS OF OVEREXPOSURE - EYE CONTACT: Causes Serious Eye Irritation
EFFECTS OF OVEREXPOSURE - SKIN CONTACT: May be absorbed through the skin in harmful amounts. Causes skin irritation.
Allergic reactions are possible.
EFFECTS OF OVEREXPOSURE - INHALATION: Harmful if inhaled. High gas, vapor, mist or dust concentrations may be harmful if
inhaled. Avoid breathing fumes, spray, vapors, or mist. High vapor concentrations are irritating to the eyes, nose, throat and lungs.
Prolonged or excessive inhalation may cause respiratory tract irritation. Constituents of this product include crystalline silica dust
which, if inhalable, may cause silicosis, a form of progressive pulmonary fibrosis. Inhalable crystalline silica is listed by IARC as a
group I carcinogen (lung) based on sufficient evidence in occupationally exposed humans and sufficient evidence in animals.
Crystalline silica is also listed by the NTP as a known human carcinogen. Constituents may also contain asbestiform or non-
asbestiform tremolite or other silicates as impurities, and above de minimus exposure to these impurities in inhalable form may be
EpoxyShield / Solvent-Based Professional Floor Coating - Pigmented Coating