Use and Care Manual
TECHNICAL DATA
EPOXYSHIELD
®
SOLVENT-BASED PREMIUM CLEAR COATING
Rust-Oleum Corporation Form: GDH-355
11 Hawthorn Parkway Phone: 877•385•8155 Rev.: 050514
Vernon Hills, Illinois 60061 www.rustoleum.com
An RPM Company
PHYSICAL PROPERTIES .
SOLVENT-BASED PREMIUM CLEAR COATING
Resin Type
Amine Cured Epoxy
Pigment Type
None
Solvents
Oxsol 100, Methyl Acetate
Weight*
Per Gallon
9.0 lbs.
Per Liter
1.1 kg
Solids*
By Weight
77.5%
By Volume
76.0%
Volatile Organic Compounds*
<100 g/l (0.83 lbs./gal.)
Mixing Ratio
2:1 Base to Activator by volume
Recommended Dry Film
Thickness (DFT) Per Coat
2.5-5.0 mils
(62.5-125µ)
Wet Film to Achieve DFT
(Unthinned Material)
3.0-7.0 mils
(75- 175µ)
Theoretical Coverage at
1 mil DFT (25µ)
1,219 sq.ft./gal. (30.0 m
2
/l)
Practical Coverage at Recommended DFT
(assumes 15% material loss)
500 sq.ft./gal. (23 m
2
/l) on painted surfaces
250 sq.ft./gal. (46 m
2
/l) on bare concrete
Induction Period
None
Pot Life @ 70-80°F (21-27°C) and
50% Relative Humidity
90 minutes
Dry Times at 70-80°F
(21-27°C) and 50%
Relative Humidity
Lt. Foot Traffic
10 hours
Hv. Foot Traffic
24 hours
Vehicle Traffic
4 days
Shelf Life
5 years
Flash Point
Base Component: 31°F (-1°C) – Activator Component: 234°F (112°C)
Safety Information
For additional information, see MSDS
* Activated material.
Calculated values are shown and may vary slightly from the actual manufactured material
The technical data and suggestions for use contained herein are correct to the best of our knowledge, and offered in good faith. The statements of this literature
do not constitute a warranty, express, or implied, as to the performance of these products. As conditions and use of our materials are beyond our control, we
can guarantee these products only to conform to our standards of quality, and our liability, if any, will be limited to replacement of defective materials. All
technical information is subject to change without notice.