SDS

Date Printed: 2/25/2020
STORAGE: Keep containers tightly closed. Isolate from heat, electrical equipment, sparks and open flame. Contents under
pressure. Do not store above 120 ° F. Store large quantities in buildings designed and protected for storage of flammable aerosols.
Keep away from heat, sparks, flame and sources of ignition. Avoid excess heat. Product should be stored in tightly sealed
containers and protected from heat, moisture, and foreign materials.
Advice on Safe Handling of Combustible Dust: No Information
8. Exposure Controls / Personal Protection
Chemical Name CAS-No.
Weight %
Less Than
ACGIH TLV-
TWA
ACGIH TLV-
STEL
OSHA PEL-TWA
OSHA PEL-
CEILING
Acetone 67-64-1 40.0 250 ppm 500 ppm 1000 ppm N.E.
Propane 74-98-6 20.0 N.E. N.E. 1000 ppm N.E.
Titanium Dioxide 13463-67-7 15.0 10 mg/m3 N.E. 15 mg/m3 N.E.
n-Butyl Acetate 123-86-4 15.0 50 ppm 150 ppm 150 ppm N.E.
Hydrotreated Light Distillate 64742-47-8 15.0 N.E. N.E. N.E. N.E.
Dimethyl Carbonate 616-38-6 10.0 N.E. N.E. N.E. N.E.
Naphtha, Petroleum,
Hydrotreated Light
64742-49-0 10.0 N.E. N.E. N.E. N.E.
n-Butane 106-97-8 10.0 N.E. 1000 ppm N.E. N.E.
1-Methoxy-2-Propyl Acetate 108-65-6 10.0 N.E. N.E. N.E. N.E.
Hydrous Magnesium Silicate 14807-96-6 10.0 2 mg/m3 N.E. N.E. N.E.
Xylenes (o-, m-, p- Isomers) 1330-20-7 5.0 100 ppm 150 ppm 100 ppm N.E.
Barium Sulfate 7727-43-7 5.0 5 mg/m3 N.E. 15 mg/m3 N.E.
Propylene Glycol Monobutyl
Ether
5131-66-8 5.0 N.E. N.E. N.E. N.E.
Solvent Naphtha, Light Aromatic 64742-95-6 5.0 N.E. N.E. N.E. N.E.
Pigment Yellow 83 5567-15-7 5.0 N.E. N.E. N.E. N.E.
1,2,4-Trimethylbenzene 95-63-6 5.0 N.E. N.E. N.E. N.E.
Aliphatic Hydrocarbon 64742-89-8 5.0 N.E. N.E. N.E. N.E.
Carbon Black 1333-86-4 5.0 3 mg/m3 N.E. 3.5 mg/m3 N.E.
Ethylbenzene 100-41-4 5.0 20 ppm N.E. 100 ppm N.E.
Ethyl 3-Ethoxypropionate 763-69-9 5.0 N.E. N.E. N.E. N.E.
Isobutyl Methacrylate 97-86-9 5.0 N.E. N.E. N.E. N.E.
Dipropylene Glycol Monobutyl
Ether
29911-28-2 1.0 N.E. N.E. N.E. N.E.
Octane 111-65-9 1.0 300 ppm N.E. 500 ppm N.E.
Naphtha (Petroleum), Heavy
Aromatic
64742-94-5 1.0 N.E. N.E. N.E. N.E.
Methyl Ethyl Ketoxime 96-29-7 1.0 10 ppm N.E. N.E. N.E.
Cobalt 2-Ethylhexanoate 136-52-7 1.0 N.E. N.E. N.E. N.E.
PERSONAL PROTECTION
ENGINEERING CONTROLS: Use process enclosures, local exhaust ventilation, or other engineering controls to control airborne
levels below recommended exposure limits. Use explosion-proof ventilation equipment. Provide general dilution of local exhaust
ventilation in volume and pattern to keep TLV of hazardous ingredients below acceptable limits. Prevent build-up of vapors by
opening all doors and windows to achieve cross-ventilation.
RESPIRATORY PROTECTION: A respiratory protection program that meets OSHA 1910.134 and ANSI Z88.2 requirements must be
followed whenever workplace conditions warrant a respirator's use. A NIOSH/MSHA approved air purifying respirator with organic
vapor cartridge or canister may be permissible under certain circumstances where airborne concentrations are expected to exceed
exposure limits.
SKIN PROTECTION: Use gloves to prevent prolonged skin contact. Nitrile or Neoprene gloves may afford adequate skin protection.
EYE PROTECTION: Use safety eyewear designed to protect against splash of liquids.
OTHER PROTECTIVE EQUIPMENT: Refer to safety supervisor or industrial hygienist for further guidance regarding types of
personal protective equipment and their applications.
HYGIENIC PRACTICES: Wash thoroughly with soap and water before eating, drinking or smoking. Remove contaminated clothing
immediately and launder before reuse.
Engineering Measures for Combustible Dust: No Information
Page 4 / 7