Instruction manual
84
This configuration uses a SA-ZX3 Keypad
Splitter hub to connect up to three UNO-S2 key-
pads to one CAV6.6 UNO keypad port. For clean
installations, use RJ-45 CAT-5 patch cables with
the T568A configuration.
To connect from the SA-ZX3 to an RJ-45 wall
plate (optional), use the patch cables to wire for
the wall plate to the keypad. Connect the con-
troller keypad port using the patch cable.
Mount the SA-ZX3 Keypad Splitter hub near the
controller using screws or hook and loop fasten-
er. The SA-ZX3 requires a 12VDC 1A power sup-
ply, such as the Russound 1201A Power Supply.
SA-ZX3 and UNO-TS2 Touchscreens
The CAV6.6 supports ONE UNO-TS2 touch-
screen AND up to five UNO keypads per con-
troller, connected directly to the controller via
the Keypad Ports.
If two or more touchscreens will be used in a
system, after the first UNO-TS2 is connected to
the controller’s Keypad Port, additional (up to
five) UNO-TS2s must be connected to the con-
troller via an SA-ZX3, with only one UNO-TS2 per
splitter per zone. UNO-S1/S2 keypads can
share the SA-ZX3 with an UNO-TS2, but they
must be configured for the same zone.
SAMPLE SYSTEM CONFIGURATION 3
Zone Keypad Expansion
Components List:
1 - CAV6.6 Controller
3 - UNO-S2 Keypads
1 - SA-ZX3 Keypad Splitter
1 - 1201A 12VDC Power Supply
1 - PlateMateâ„¢ MOD3D
3 - MOD RJ-45 CAT-5