AUTOMATIC FLUSH VALVE
INSTALLATION
The automatic
flush
valve
must be mounted to a supportive base. DO NOT suspend automatic flush valve
directly
from
the
·water
filter. The automatic flush valve has 6 holes on the back
of
the unit. The four
larger holes are
used
for
securing the faceplate to the unit. The 2 smaller holes are used to mount the
unit directly to a supportive base. (Remove the faceplate to mount unit to base)
This unit may
be
mounted
in
either direction (Horizontal/Vertical). Vertical installation
is
recommended
for optimum performance. All necessary
co~tions
and tubing are provided
in
our optional AFV-KIT.
If
purchasing
from
another source, please make sure that
W'
braid reinforced flexible
pvc
tubing with a
215
PSI
rating is
used.
AFV-KIT consists
of
the following:
(2) W' Barb x W'
NPT
Male Hose Fittings
(2)
SAE
Size 8 Stainless Steel
Worm
Drive Clamps
(24")
W' Braid Reinforced Flexible PVC Tubing (Rated at 215 PSI)
(1) Roll
of
thread seal tape
A suggested installation diagram is shown at right:
<
Wrap thread seal tape around threaas
of
barb fitting male
end
before threading into pvc
and
brass ball valves.
Secure flexible tubing to barb fittings at hose end with clamps.
WARNING
SUGGESTED INSTALLATION
Do not apply electrical power to the unit unless the unit
is
fu11y
assembled and mounted. Always
disconnect power source before working
on
this unit.
The.
valve
is
under pressure. Discharge
of
fluids
wi11
occur during
any
cycling
of
the valve when unit is
insta11ed.
OPERATION
Plug the cord
set into a proper power source. The automatic flush valve will cycle and the timing sequence
will begin. To change the timing sequence, simply change the code setting (0-9)
5 minutes to
24
hours,
and
the timer
will
reset. The test button may be used to cycle the unit at any time. Unit must
flush
at
least once
every
24
hours. Flush time is 3 seconds and cannot be adjusted.
MAINTENANCE
Periodic maintenance
is
recommended to ensure long, dependable service
from
your automatic flush valve.
Check power cord
for
breaks
in
the outer jacket or damage to the plug. The valve should
be
checked
for
leakage at the downstream side and all connections from the valve to the filter.
.,