Install Instructions
Runtal noRth ameRica, inc. US Tel: 800-526-2621 s Canadian Tel: 888-829- 4901 s www.runtalnorthamerica.com
Operation & Maintenance
ma i n t e n a n c e & cl e a n i n g
Your Runtal OmnipanelII (OP II) has been designed to require the absolute minimum maintenance and care
under normal use. However, care should be taken when cleaning the surface of the panel. Periodically vacuum
across the top of the grille to remove dust from the grille. A slight odor may be noticeable during initial
operation and will dissipate within a few hours.
The OPII’s powder coated finish provides an elegant yet durable finish to a welded steel product.
Occasional cleaning of this finish is best done with a water dampened cloth. Under no circumstances should
abrasive cleaner be used. Before cleaning make sure the power has been turned off at the circuit breaker
panel, and the heating element is cool. Be sure to restore power when cleaning and maintenance is complete.
All other servicing should be performed by qualified service personnel.
For installation of multiple OPII radiators, the following chart should be used.
The chart indicates supply voltage, circuit breaker rating, minimum wire size, and maximum total
wattage of electric radiators on the circuit.
ma x i m u m Wat ta g e o n a ci R c u i t
Voltage A.C. Circuit Breaker Size Maximum Wattage
Minimum
Wire Size
120 15 Amp 1440 14/2 with Ground
208 15 Amp 2496 14/2 with Ground
240 15 Amp 2880 14/2 with Ground
IMPORTANT INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS
5
Model H B 24” Width
OP II-9 26.1 in 14.6 in 425 Watts
OP II-12 34.8 in 23.4 in 700 Watts
OP II-15 43.6 in 32.1 in 700 Watts
9 Panel
OmnipanelII
Side View
9 Panel
OmnipanelII
Front View
3
3
⁄4”
2”min. Floor Clearance
H
B
5
3
⁄4”
O
N
O
F
F
24”
H
OP II-9