User's Manual

WEB GUI description RNU4000BS Base Station User Manual
12 Runcom Technologies Ltd.
Monitoring screen The figures below represent the “Monitoringworking screens and provides the next info as
described in the table below:
Menu
Section
Description
Monitoring
Status
Synchronization
Provides the BS synchronization operational and configuration
status:
1PPS lock status “Lock” or “Unlock” indicates
the 1PPS BS GPS synchronization status
Modem status indicates the BS RF status:
- “running” BS RF activated / normal BS operation
- “Not running” BS RF inactivated / BS is not
operational, management is available
1PPS source indicates the 1PPS source
configuration (see figure “1PPS synchronization
source configuration” below)
- “GPS via Antenna” default configuration
Physical connection status “Connected” or “Not
Connected”- indicates physical connection status of BS
external connectors “1PPS input” or “GPS”
GPS lock status “Lock” or “Unlock” indicates
the BS GPS lock status
GPS initialization status “Initialized” or “Failed”
indicates the BS GPS initialization status
Hold over time “0sec to 14400sec indicates the
time of Hold over timer. The timer starts once the BS GPS
loss the 1PPS synchronization “Unlock”
- “14400 sec” default
Hold over time expired “Not expired” or
“expired” indicates the Hold over timer status
- Once the timer is expired (14400sec), the BS RF becomes
inactivated and that is in order to prevent interference to other
BS’s.
Sync change state counter counting indicates
the BS GPS 1PPS synchronization “unlock” states number “
Radio Status
Provides BS sector configuration status info:
Max DL Modulation
Max DL Modulation
Initial Noise BS receiver initial noise indicates
spectrum radio channel quality of the BS working frequency
Note: Desirable is to obtain initial noise figure less than -
117dbm
Initial TX power
WiMAX
Connection
Provides BS connection status info:
BS ID indicates the BS ID
Frequency indicates the BS central working
frequency
Bandwidth Profile indicates the radio BW and
the TX/RX symbols ration
Preamble ID indicates the BS preamble ID
No. connected UT’s – indicates the quantity of
connected CPE’s to the BS
No. of known NBR Bases Handover feature /
indicates the quantity of recognized by BS other neighbor
BS’s
Note: N/A for current BS WEB GUI version