User's Manual
WEB GUI description RNU4000BS Base Station User Manual
10 Runcom Technologies Ltd.
2.1 WEB GUI Menu description
The table below describes the WEB GUI Menu options and their functionalities
Menu
Section
Description
General Information
General
Provides BS related HW/SW info
IP Status
Provides BS ETH interface IP addresses status
Configuration
General
General
Provides RF parameters and MCS settings
IP
Configuration
IP Configuration
Provides BS related IP addresses settings
Monitoring
Status
Synchronization
Provides BS synchronization status
BS Status
Provides BS sector configuration status
Connection
Connection
Provides BS RF parameters configuration status
Antenna Status
Provides BS antenna configuration status
CPE Info
CPE Info Query
Provides ability to obtain fast link status connection
parameters of specific CPE
CPE List
Provides list of connected CPE’s and theirs ID and
more detailed connection parameters as link status
parameters and theirs SF connection
Maintenance
Upgrade
SW Upgrade
Provides BS SW upgrade including all SW components
Recovery
Change Version
Provides swap between BS SW version (current
running and the previous one)
Default
Reset to Default
Provides ability to set the BS to default parameters
related to the SW version
Erase
Configuration File
Provides ability to erase the configuration file in case
if such file was downloaded to BS
2.2 WEB GUI working screens description
General Information Screen – The figure below represent the “General Information” working screen and
provides the next info as described in the table below:
Menu
Section
Description
General Information
General
Provides BS ID related info:
HW – Product Type
SW – FW /FPAGA version
BS ID – BS MAC address
IP Status
Provides BS ETH interface IP addresses status:
BS ETH interface LAN configuration –
IP /subnet/ GW address
ASN GW interface configuration - GW IP and
Authentication address for connection with BS
ASN BS DHCP client – ENB/DSB