User's Manual
PicoPlus Base Station User Manual Installing the PicoPlus BS
Runcom Technologies Ltd. CONFIDENTIAL 27
3.4 End-to-End Traffic Test
After the system is installed, it is recommended to perform an End to End (E2E) test to test
communication and traffic transference over the link.
In this test, a computer connected to a CPE (that is configured to operate with the BS)
sends a ping message towards the NOC (Network Operations Center) and AAA
(Authentication, Authorization and Accounting center). Receiving an answer from the
NOC/AAA side by the CPE's PC assures that the system is configured and operating
properly.
The following figure shows the end-to-end test elements.
To perform the test
1. Ensure that the BS is configured with the:
• Center frequency
• ASN-GW IP address and security parameters (see 2.4.1)
2. Connect the BS to a CPE configured with the:
• Center Frequency
3. Connect a computer configured to communicate with the CPE (see section 2.3.2 – using
the CPE IP address subnet) to the CPE Ethernet port using a cross-cable.
4. Use Telnet to send a ping command from the CPE computer to the NOC IP Address.