3. In the BS Settings area, define the following:
• Sector Frequency [KHz] – central frequency between the upper and lower cutoff
frequencies.
• The default IP Address of the BS is 192.168.0.20. To change the address, click the
Board IP Change button.
• Click the (Update) BS Settings button to save the changes on to the BS.
2.4.1.2 Setting BS Minimum Parameters via a Standard MIB Browser
Configure additional parameters for communication with the ASN-GW
Use a standard MIB browser to configure the following ASN-GW and Security parameters:
• ASN-Gateway IP Address
• R6_mode (disable/enable)
GdbNvAirLink.R6Mode 0x00000002
GdbNvAirLink.OperationMode 0x00000000
GdbNvAirLink.SectorProfile.MacProfile.m_CsAssocMode 0x00000002
# router IP parameter at the ASN-GW in Hex (10.0.1.101 = 0x0A000165)
GdbNvAirLink.SectorProfile.R6Profile.m_AsnGwIp 0x0A000165
# GRE port at the ASN-GW connect to the BS in Hex (10.220.0.101 = 0x0ADC0065)
GdbNvAirLink.SectorProfile.R6Profile.m_AuthenticatorIp 0x0ADC0065
# Setting for R6
GdbNvAirLink.BootMode 1
GdbNvMngmnt.Logger.fLogEnable 1
GdbNvMngmnt.Logger.LevelFilter 0
GdbNvMngmnt.Logger.severityFilter 0
• Null_Authentication
#GdbNvAirLink.SectorProfile.UtCapabilitiesProfile.SecurityProfile.m_EapInitialNetworkSu
pport 0
#GdbNvAirLink.SectorProfile.UtCapabilitiesProfile.SecurityProfile.m_EapReEntrySupport
0
#GdbNvAirLink.SectorProfile.UtCapabilitiesProfile.SecurityProfile.m_CMACSupport 0
• Authentication_EAP_TTLS
GdbNvAirLink.SectorProfile.UtCapabilitiesProfile.SecurityProfile.m_EapInitialNetworkSupp
ort 1
GdbNvAirLink.SectorProfile.UtCapabilitiesProfile.SecurityProfile.m_EapReEntrySupport 1
GdbNvAirLink.SectorProfile.UtCapabilitiesProfile.SecurityProfile.m_CMACSupport 1
• Standalone_mode
GdbNvAirLink.BootMode 1