User's Manual
RCMS Application PicoPlus Base Station User Manual
36 CONFIDENTIAL Runcom Technologies Ltd.
4.3.3.2 CPE Control Buttons
The following CPE control buttons are available:
Per…. Control Button Description
Connect
Retry to establish a connection to this CPE
(when no connection exists).
Reset
Reset the connection between this CPE and the
BS.
CPE
More
Specify the connection settings for this CPE
(useful just before using the Connect button).
Connect All Retry to establish a connection to all CPEs Global
Reset All
Resets the connection between all of the CPEs
and the BS.
Note: After performing Reset or Reset All, click the Refresh button to display the updated
data.
4.3.3.3 CPE Polling Interval
To set or modify the polling interval
Check mark the Poll Every field and specify the time interval (in seconds) in which polling
will be performed.
4.3.4 SW and FPGA Version Status
The SW and FPGA Version area provides information on the currently running and stored
FPGA and software versions.
• The bank storing the currently running version is marked as Running.
• The bank used for temporary storage is marked as Idle.
• Use the Skip button to switch between the banks.
Two additional operation buttons are provided:
• Defaults – revert to default SW and FPGA versions.
• BS Reset – reboots the BS and loads the relevant BANK, according to user
specifications.