User's Manual
CPE-O-R-WS User Manual
8 Runcom Technologies Ltd.
3.3 Operating and Configuration of the CPE-O-R-WS
3.3.1 Device Logic connection
Connect the CPE to the PoE adapter port ODU using a standard CAT 5 Ethernet cable. The CPE is powered from a 24V
DC power supply from a power adapter. The power adapter operates from 90-250V AC range. Once the device is
powered, the user should wait for about 2 minutes before the device becomes operational. For CPE with the RUN LED
indicator, a slowly flashing light indicates the system has completed the startup procedure.
To connect PC, LAN switch or other type of IP device to the CPE product, connect a standard CAT5 Ethernet cable and
connect to the NET port of the PoE. Once it is connected the CPE LAN LED indicator should come on.
Figure 4: PoE Connectivity
3.3.2 CPE Configuration
Connect Laptop to the Net port of the PoE and open Google Chrome Browser. Connect to IP 192.168.0.1 and
follow the instruction in paragraph 4 to configure the CPE, to the required channel frequency obtained by AFAS
from the TVWS Data Base.
Warning! – use discrete channels settings only!