Installation guide
142 Runco WindowWall Installation Guide
Environmental Specifications
Specification Maximum Minimum Optimal Notes
Temperature
operating, LCD tile
operating, Quad Input Manager Module
operating, Power supply module
35° C
95° F
45° C
113° F
45° C
113° F
0° C
32° F
10° C
50° F
10° C
50° F
20° C
+/- 3° C
20° C
68° F
20° C
68° F
All performance
specifications are
maintained within this
temperature range.
non-operating, LCD tile
non-operating, Quad Input Manager Module
non-operating, Power supply module
50° C
122° F
85° C
122° F
85° C
122° F
–20° C
–4° F
–20° C
–4° F
–20° C
–4° F
20° C
+/- 10° C
Altitude (barometric pressure) 2000m Above sea level, or
equivalent barometric
pressure. De-rate
temperature 10° for every
1km above 1000m.
Humidity
operating, LCD tile
operating, Quad Input Manager Module
operating, Power supply module
80% R.H.
80% R.H.
80% R.H.
20% R.H.
20% R.H.
20% R.H.
non-condensing