Installation guide

134 Runco WindowWall Installation Guide
All LCD backlights turn
on with IR remote.
IR sensor is connected
Quad Input Manager
Module A is configured
and cabled to the other
Quad Input Manager
Module (per your
configuration).
Comm connection to
display tiles is good.
IR sensor must be plugged in to ‘A’ Quad
Input Manager Module.
Quad Modules must be cabled together via
RS-485
There must be one and only one Quad Input
Manager ModuleA
If a Quad Input Manager Module has been
newly connected, you may have to turn off
and then back on to synchronize those
displays. If in doubt, A/C power cycle the
system after all connections have been made.
“Info Pane” appears on
all displays when
menus are on. (The
“info pane” is the gray
square which shows
the display address,
position sensor
information and
information about the
target menu).
Video connection is
good.
Equalization is set within
reason.
If you see no video it all, the equalization
could be bad
If some displays do not respond, you may
have out of date firmware. All Quad Input
Manager Modules must have the same rev
level of firmware.
UNIT STATUS menu
appears on all displays
when the
MONITOR
button is pressed.
Properly functioning
display wall.
If a different menu appears on some displays,
you may have mismatched firmware. All Quad
Input Manager Modules must have the same
rev level of firmware, and that firmware must
be “cloned” to all 4 of the processors.
UNIT STATUS menu:
Temperature is within
reason.
Backlight shows OK
Voltage is >22 v
The display tile (LCD)
and its interface board
are functioning
properly.
These three items are reported to the Quad
Input Manager Module by the LCD interface
board (on the display tile) over the Comm
connection. If the voltage is 0 the voltage
meter is not functioning on the LCD interface
board (some early prototype systems did not
have this meter). If the voltage is low, there
may be too much drop in your power cables.
UNIT STATUS menu:
Quad Module
Temperature is within
reason and Fan is OK.
The Quad Input
Manager Module
cooling system is
operating normally.
This portion of the menu only shows up on
processor 1 of a Quad Input Manager Module.
Check for proper fan function and proper
cooling of the rack.