Configuration Scenarios
118 Runco WindowWall Installation Guide
• An LCD can display its own digital input, its immediate neighbor or the “loop”.
• The loop out connector can display any of the five inputs.
• The “loop” can be any of the four inputs. It can also be the Dual Link in
connector but in that case, the Loop Out connector must also be displaying the
Dual Link In input.
The QUAD MODULE ROUTE menu allows you to set these switches. There is one QUAD
MODULE ROUTE menu for each Quad Input Manager Module in your system. There are
two parts to the menu. Each part gives the same information in a different way. The
top part of the menu shows you what input (1,2,3,4 or Link In) will be shown on each
output (LCD 1, LCD 2, LCD 3, LCD 4 and Loop Out).
The bottom part of the menu shows you how each of the seven switches are set. You
can change the switches using either part of the menu. The other part will
automatically update. It may be frustrating to try to make changes in the switches
using the top part of the menu, because not every combination of input to output is
allowed. Changing one line on the top may cause changes in other lines. On the
other hand, using the bottom part of the menu sets the switches directly so there are
no disallowed states. As you set the switches on the bottom part of the menu, the
top part of the menu will change to show the effect of your changes.
All of the scenarios in this document use only the bottom part of the menu to set up
source routing.
Note: Quad Module Route A menu.
Quad Module Route A
1 2 3 4 Link In
LCD 1
LCD 2
LCD 3
LCD 4
Loop Out
Switch 1 Loop
Switch 2 Loop
Switch 3 Loop
Switch 4 Loop
Internal Loop Digital 3
External Loop Digital 4
Use Loop Internal