Configuration Scenarios
Runco WindowWall Installation Guide 115
Complex Configurations
It is possible to design systems that don’t fall into any of the above scenarios, but not
all combinations of inputs on sub walls are possible. A system cabled for such a
complex configuration may or may not be able to also have some of the simpler
configurations.
Scenario 7: Multiple Large Sub Walls
The previous scenario was restricted such that only one sub wall in a Runco
WindowWall could be larger than a single Quad Input Manager Module. If you desire
more than one sub wall that is larger than four displays, there are certain restrictions.
You must cable the loop connections sequentially among the quad modules that
make up each sub wall. Since a sub wall that spans more than one Quad Input
Manager Module module uses the external loop, a sub wall is restricted to using
inputs from only the first Quad Input Manager Module in the loop through chain.
Note: 4 x 4 Runco WindowWall with two 4 x 2 sub walls. One Big Picture is also available, but
each sub wall is limited to four sources.
A1
A2
A3 A4
B1
B3
C1 C2 D1
B2
B3
D2
C3 C4 D3 D4
A
Loop Out
Dual Link In
Loop Out
Dual Link In
Loop Out
Dual Link In
Digital 1 Digital 2 Digital 3 Digital 4
B
Digital 1 Digital 2 Digital 3 Digital 4
Digital 1 Digital 2 Digital 3 Digital 4
Loop Out
Dual Link In
Digital 1 Digital 2 Digital 3 Digital 4
D
Switch 1 Loop
Switch 2 Loop
Switch 3 Loop
Switch 4 Loop
Internal Loop Digital 1
X External Loop Digital 2
Use Loop External
Switch 1 Loop
Switch 2 Loop
Switch 3 Loop
Switch 4 Loop
Internal Loop Digital 1
X External Loop Dual Link In
Use Loop External
Switch 1 Loop
Switch 2 Loop
Switch 3 Loop
Switch 4 Loop
Internal Loop Digital 3
External Loop Digital 3
Use Loop External
Quad Module Route C
Quad Module Route B
Quad Module Route A
Switch 1 Loop
Switch 2 Loop
Switch 3 Loop
Switch 4 Loop
Internal Loop Digital 1
X External Loop Dual Link In
Use Loop External
Quad Module Route D
Wall Width 2
Wall Height 4
Unit Row 1
Unit Column 2
X Wall Mode
Wall Width 2
Wall Height 4
Unit Row 2
Unit Column 2
X Wall Mode
Wall Width 2
Wall Height 4
Unit Row 3
Unit Column 1
X Wall Mode
Wall Width 2
Wall Height 4
Unit Row 4
Unit Column 1
X Wall Mode
Wall Width 2
Wall Height 4
Unit Row 3
Unit Column 2
X Wall Mode
Wall Width 2
Wall Height 4
Unit Row 4
Unit Column 2
X Wall Mode
Wall Width 2
Wall Height 4
Unit Row 1
Unit Column 2
X Wall Mode
C
Source 1 Source 2 Source 3
Source 9
Source 4 Source 5 Source 6
Source 7 Source 8
Source 7 Source 8
Source 4
Source 6
Source 9
Source 8 Source 8
Note the cabling difference. A must loop out to C. B must loop out to D
Any Source from A can be spread on the left half. Any source from B can be spread
on the right half
Wall Width 2
Wall Height 4
Unit Row 1
Unit Column 1
X Wall Mode
Wall Width 2
Wall Height 4
Unit Row 4
Unit Column 2
X Wall Mode
Wall Width 2
Wall Height 4
Unit Row 2
Unit Column 1
X Wall Mode
Wall Width 2
Wall Height 4
Unit Row 4
Unit Column 1
X Wall Mode
Wall Width 2
Wall Height 4
Unit Row 3
Unit Column 1
X Wall Mode
Wall Width 2
Wall Height 4
Unit Row 3
Unit Column 2
X Wall Mode
Wall Width 2
Wall Height 4
Unit Row 2
Unit Column 1
X Wall Mode
Wall Width 2
Wall Height 4
Unit Row 2
Unit Column 2
X Wall Mode
Wall Width 2
Wall Height 4
Unit Row 1
Unit Column 2
X Wall Mode