Specifications
Table Of Contents
- TWO YEAR LIMITED WARRANTY
- Safety Precautions
- 1. Introduction
- 2. Controls and Functions
- 3. Installation
- 3.1 Remote Control
- 3.2 Quick Setup
- 3.3 Installation Considerations
- 3.4 Installing the Projection Lens, Lamp and Cooling
- 3.5 Installing the Optional CineWide Lens Mount
- 3.6 Mounting the SC-1
- 3.7 Connections to the SC-1 and DHD Controller
- Input Panel Access
- Connecting the DHD Controller to the SC-1
- Connecting Source Components to the DHD Controller
- RS-232 Controller Connection
- Connecting 12-volt Trigger Outputs to External Equipment
- Connecting an External IR Receiver to the DHD Controller
- Connecting an External Power Supply/Ballast to the Projection Head
- Connecting to AC Power
- 3.8 Turning on the Power
- 3.9 Maximizing Light Output
- 3.10 Adjusting the Picture Orientation
- 3.11 Primary Lens Adjustments
- 3.12 Installing and Adjusting the CineWide Anamorphic Lens
- 3.13 Calibrating Projector Input 2 (DVI)
- 3.14 Working With the Lamp
- 4. Operation
- 5. Maintenance and Troubleshooting
- 6. Serial Communications
- 7. Specifications

Serial Communications
104 Runco SC-1 Owner’s Operating Manual
P
RELI
M
INARY
Image Preset Commands
CUSTOM1 NA YES Loads “Custom 1” image preset
CUSTOM2 NA YES Loads “Custom 2” image preset
DAY NA YES Loads “ISF Day” image preset
NIGHT NA YES Loads “ISF Night” image preset
PRESET? NA NA Returns currently-selected preset
(ISF Day, ISF Night, Custom 1 or Cus-
tom 2)
Input Position Commands
IHEIGHT -100/100 YES Sets the value for input height
IHEIGHT? NA NA Returns input height value
IHPOS -100/100 YES Sets a value for horizontal input position
IHPOS? NA NA Returns input horizontal position value
IVPOS -100/100 YES Sets a value for vertical input position
IVPOS? NA NA Returns input vertical position value
IWIDTH -100/100 YES Sets the value for input width
IWIDTH? NA NA Returns input horizontal width value
OVERSCAN 0/10 YES Sets the overscan percentage
OVERSCAN? NA NA Returns overscan percentage
Output Shift Commands
OHEIGHT -100/100 YES Sets the value for output height
OHEIGHT? NA NA Returns output height value
OHPOS -100/100 YES Sets the value for output horizontal posi-
tion
OHPOS? NA NA Returns output horizontal position value
OVPOS -100/100 YES Sets the value for output vertical position
OVPOS? NA NA Returns output vertical position value
OWIDTH -100/100 YES Sets the value for output width
OWIDTH? NA NA Returns output horizontal width value
Table 6-1. Serial Commands (continued)
Command
Parameter
(min/max)
Value
Stored?
Description