Specifications

28
GET Commands
What are GET Commands?
They are commands for outputting TXD such as adjustment data from the internal microcomputer of the plasma
display to a PC.
Adjustment data, etc., is output in ASCII code.
NOTE: Command names are given inside brackets < >.
Data output format
STX (o2hex) Data Data .... Checksum ETX (03hex)
NOTE:
1) GET commands will be invalid when no ID NO. Set is assigned to the set.
2) GET commands will be invalid when wildcard (*) is used in the ID No. Set when sending the command.
1) <GST> (GET STATUS)
Order Data Contents Size Remarks
1 Display data 3byte See below
2 Power data 3byte See below (The third character is sub input)
3 Input function data (main) 3byte Input data when GST is received (INPUT1 to 5 is displayed as IN1 to 5)
4 Input function data (sub) 3byte Sub input data when GST is received
Note 3
(INPUT1 to 5 is displayed as IN1 to 5)
5 Screen size data 1byte See below
6 2-screen display 1byte 0: OFF (1 screen) 1: 2-SCREEN 2: PinP (lower right)
3: PinP (upper right) 4: PinP (upper left) 5: PinP (lower left)
6: PoutP
7 FUNCTIONAL LOCK data 1byte 0: LOCK OFF 1: BUTTONS LOCK 2: IR LOCK
3: IR & BUTTONS LOCK 4: MEMORY LOCK
8 Dummy Data 3byte (3-digit number)
9 Temperature data 2 3byte (Internal temperature: Reference value)
o
C
Note 1
10 Temperature data 3 3byte (Internal temperature: Reference value)
o
C
Note 1
11 Serial 15byte
12 Dummy data 3byte (3-digit number)
13 Dummy data 3byte
14 HOURMETER 5byte Display the time.
15 Checksum 2byte
Display data First character Generation data: 4 (xed)
Second character Inch data: 4 (43 inches), 5 (50 inch)
Third character Destination data: M (xed)
Power Data First character Power state & signal state
Second character
PN (POWER ON & normal signal input)
PL (POWER ON & no input)
PO (POWER ON & OUT OF RANGE signal input)
SN (Normal standby)
SW (Standby by AUTO POWER OFF)
SS (Standby by SD or PD)
Third character
Sub input signal state during multi-screen display
N (Normal signal input) L (No input)
O (OUT OF RANGE signal input)
Screen size data First character
(0) Pix by Pix or Letterbox, (1) STD (4:3), (2) ANAMPHC 16:9, (3) Letterbox
(1080i), (4) Cinema, (5) Virtualwide, (8) Letterbox (1035i), (9) Underscan
NOTE 1) During standby and immediately after POWER ON, the proper value is not output. In this case, wait a moment after POWER ON, then
get the data. The temperature data is output as a reference (the values are not guaranteed values). Normally, refer to temperature data 3.
NOTE 2) During standby and during 1-screen display, dummy data (symbol) is output.
NOTE 3) During standby and during 1-screen display the values stored in memory for the product are output.