Specifications
23
Command
Name
Full Name RS-232C
Adjustment
Validity
Normal
Validity
Numerical
Direct
Validity
Description
C
CTP COLOR TEMP: ******** ● Displays the current COLOR TEMP.
CTPS01 COLOR TEMP.: 1 ○ Sets the COLOR TEMP. to LOW (equal to -3000K)
CTPS02 COLOR TEMP.: 2 ○ Sets the COLOR TEMP. to MID-LOW (equal to -2000K)
CTPS03 COLOR TEMP.: 3 ○ Sets the COLOR TEMP. to MIDDLE (±OK, standard)
CTPS04 COLOR TEMP.: 4 ○ Sets the COLOR TEMP. to MID-HIGH (equal to +1000k)
CTPS05 COLOR TEMP.: 5 ○ Sets the COLOR TEMP. to HIGH. (equal to +2000K)
CTR CTI: ### ● Displays the current color transient improvement setting, to make image
have clearer color contours.
CTRS00 CTI: OFF ○ Sets CTI to OFF.
CTRS01 CTI: ON ○ Sets CTI to ON.
D
DIN ○ ○ Turns off the OSD display.
DIY OSD: ON ○ ○ Turns on the OSD display.
DNR VIDEO NR: ##### ● Displays the current DNR setting.
DNRS00 VIDEO NR: OFF ○ Sets the VIDEO NR to ON.
DNRS01 VIDEO NR: LOW ○ Sets the VIDEO NR to LOW.
DNRS02 VIDEO NR: MIDDLE ○ Sets the VIDEO NR to MIDDLE.
DNRS03 VIDEO NR: HIGH ○ Sets the VIDEO NR to HIGH.
DOF - ○ ○ Clears the current displayed OSD.
DPR DPR ○ ○ Resets the still image repeat function.
DW0 # ○ ○ Reduces adjustment value by 10.
DW n # ○ ○ Reduces adjustment value by n (n =1 to 9)
DWF # ○ ○ Sets the adjustment value to the minimum value.
E
ENH H. SHARPEN: *** ○ ○ Adjusts H. SHARPEN.
ENV V. SHARPEN: *** ○ ○ Adjusts V. SHARPEN.
ESV ENERGY MODE: ****** ● Displays the current ENERGY MODE setting.
ESVS00 ENERGY MODE: STANDARD ○ Sets the ENERGY MODE setting to STANDARD.
ESVS01 ENERGY MODE: MODE1 ○ Sets the ENERGY MODE setting to MODE1 (energy saving)
ESVS02 ENERGY MODE: MODE2 ○ Sets the ENERGY MODE setting to MODE2 (energy saving)
ESVS03 ENERGY MODE: MODE3 ○ Sets the ENERGY MODE setting to MODE3 (long life)
ESVS04 ENERGY MODE: AUTO ○ Sets the ENERGY MODE setting to AUTO.
F
FCA FAN: AUTO ○ Sets the fan rpm control to AUTO.
FCL ####### ● Displays the current FUNCTIONAL LOCK setting.
FCLS00 LOCK OFF ○ Clears the FUNCTIONAL LOCK.
FCLS01 BUTTONS LOCK ○ Locks the main-control panel button control.
FCLS02 IR LOCK ○ Locks the remote-control button control.
FCLS03 BUTTONS & IR LOCK ○ Locks both main-control panel and remote button control.
FCLS04 MEMORY LOCK ○ Sets the MEMORY LOCK
FCM FAN: MAX ○ Sets the fan rpm control to maximum.
FDT FUNCTION DEFAULT ● Executes FUNCTION DEFAULT.