Owner`s manual

VideoWall™/CineWall™ Installer/Integrator Manual 88
PR
E
LIM
INA
RY
141
system.state 1059 ? WAIT
READY
ON
FATAL.FAULT
FAULT
UNKNOWN
0
1
2
3
4
5
WAIT = waiting for lamp to cool
READY = ready for ON com-
mand
ON = at least on lamp is on
FAULT = AC power must be
cycled at the display to restart
lamps
142
temperature.c 1153 BOARD
DLP
0
5
? 0 – 125
Temperature, in Celsius.
DLP = engine
143
uart.clear 1187 RS232
AUX232
0
2
[execute]
144
uart.errors 1186 RS232
AUX232
0
2
? 0 – 32767
Resets to zero upon reaching its
maximum value.
145
uart.overflows 1185 RS232
AUX232
0
2
? 0 – 32767
Resets to zero upon reaching its
maximum value.
146
uniformity.correction 1352 =? DISABLE
ENABLE
0
1
147
vertical.lines 1263 ? 0 – 65535
Raw number of lines detected by
display.
148
video.standard 17426 ? NTSC
NTSC.60.443
PAL.50.358
PA L
SECAM
N/A
1
3
4
6
8
22
If the format is completely
unknown, or it is not a video
source, the response in N/A.
149
viewport.window.bottom 1042 =?+– 0 [–100]
:
100 [0]
:
200 [+100]
0
:
100
:
200
150
viewport.window.height 1100 ? [pixels]
Table 5-5. Operation and String Commands for VideoWall/CineWall (continued)
Row
Operation
or
String [ ST ]
Operation or
String
number
(Target)
Target or Target number must
be in parentheses.
( Target
number )
Command
types allowed
(Use only one
symbol)
Value
If numbers listed first, use num-
bers only. Data in [square
brackets] is for information only.
Value number
Notes
set
get
inc
dec