Owner`s manual

VideoWall™/CineWall™ Installer/Integrator Manual 87
PR
E
LIM
INA
RY
134
slot.target 1068 =? 0 [slot 1]
1 [slot 2]
:
39 [slot 40]
0
1
:
39
Sets (or recalls) the target slot
number for other actions. The
target slot is used by slot.action,
slot.name.clear,
slot.name.letter, and
slot.setting.)
135
source.search.status 1133 ? VIDEO.DISPLAYED
GRAPHICS.DISPLAYED
AUTO.RUNNING
AUTO.SETUP.COMPLETE
OUT.OF.RANGE
SEARCHING
DETECTED
HOLDING
IDLE
0
1
2
3
4
5
6
7
8
136
sync.type 1064 ? UNKNOWN
SOG
COMPOSITE
SEPARATE
0
1
2
3
SOG = sync on green
SEPARATE = separate H and V
sync
137
system.hours.high 1112 =? [hours / 10000]
Do not set lamp, runtime or sys-
tem hours/minutes unless
actual time was lost, such as
when electronics module is
replaced. Note: Product warran
-
ties are not based on these tim-
ers.
138
system.hours.low 4098 =? [hours mod 10000]
139
system.hours.reset 4612 [execute]
140
system.minutes 4099 =? 0 – 59
Table 5-5. Operation and String Commands for VideoWall/CineWall (continued)
Row
Operation
or
String [ ST ]
Operation or
String
number
(Target)
Target or Target number must
be in parentheses.
( Target
number )
Command
types allowed
(Use only one
symbol)
Value
If numbers listed first, use num-
bers only. Data in [square
brackets] is for information only.
Value number
Notes
set
get
inc
dec