Owner`s manual

Serial Communications
VideoWallâ„¢/CineWallâ„¢ Installer/Integrator Manual 63
PRE
L
IMINAR
Y
Command Sent Response Explanation
op 00 ascii.response = symbolic
<code>[CR]
OP 00 ASCII.RESPONSE=SYMBOLIC
The unit received the command
and has set the response type to
symbolic and replies will be ascii
characters
op 00 curtain.pattern ? <code>[CR] OP 00 CURTAIN.PATTERN=BLACK
The curtain pattern is set to
black.
op 00 ascii.response = numeric
<code>[CR]
OP 00 1137=1
The unit received the command
and has set the response type to
numeric and will reply with the
value number
op 00 curtain.pattern ? <code>[CR] OP 00 OP 00 1036=6
The curtain pattern is set to
black.
op 00 ascii.response = data <code>[CR] ACK
The unit received the command
and has set the response type to
data and will reply with only a
number
op 00 curtain.pattern ? <code>[CR] 6
The curtain pattern is set to
black.
Responses are always in ALL CAPS, regardless of how the query
was sent.
Note