Owner`s manual
Serial Communications
62 VideoWall™/CineWall™ Installer/Integrator Manual
PRE
L
IMINAR
Y
Values The Value may be sent as text or as a value number. In this column, some values have no
text, such as the command
auto.level.status. This command takes a value of
0 through 4, not “idle” or “working with black”, etc. It replies with the same numerals,
never words.
Text values can be sent in upper or lower case or with mixed case. They are listed in
UPPER CASE in the table to make it easier to see the difference between the value and
any [explanation].
[varies] means the range of acceptable values and replies varies with the type of source.
Reading the Response Two commands establish the features of the replies. (Remember the displays only reply
when individually addressed.)
ascii.eol determines the End Of Line character the display will send at the end of
every command.
ascii.response determines how you want the replies to look when they come
back to you.
• Symbolic means the replies will come back as ascii characters, if the value column
allows them.
• Numeric means that the Value Number will come back
• Data means that only the value is returned, not the preceding information
The following table shows examples of each setting for ascii.response and three
possible responses:
[none] Execute means the
command is
executed. No
character fol
-
lows the com-
mand (or the
Target, if it has
one)
op 04 lamp.hours.reset [CR]
Resets the lamp hours meter
for the Lamp in unit 04.
Table 5-1. Command Types
Symbol Meaning Example Result
Any word or character or phrase that appears between [square
brackets] is for information or clarification only. It is not sent to the
display or received from it.
Note
➤
➤