Table 4-1 lists the On-Screen codes and describes their meaning.
Table 4-1. VideoWall/CineWall On-Screen Codes
Condition Priority Each block represents 0.2 seconds
Starts with Red
Lamp is off
Door open 1 R R R
(Note 3)
Power Supply Fan
failed
2 R
Amber
DLP™ Fan failed 3 R
Amber
R
380V failed 4 R R
Amber
Optical Engine
failed
5 R R
Amber
R
Lamp failed 6 R R
Lamp off (wait, auto
off)
4
7 R R
Amber Amber
Wait (lamp off, cool-
ing)
8 R R R R
Starts with Amber
Fan Failed (non-crit-
ical)
9
Amber
R R
Lamp off (lamp
saver)
5
10
Amber Amber
R
Lamp off (ready to
turn on)
11
Amber Amber
Lamp striking
(starting)
12
Amber Amber Amber
Lamp on, no alarms 13
Amber on continuously
Notes:
1. R = Red
2. To view on-screen codes, select Unit Status from the Diagnostics menu, or press and hold the ISF NIGHT button while
simultaneouly pressing the MENU button on the remote control.
3. With Priority 1 through 6 events, to turn the lamp on, cycle AC power off, then on. If Auto Codes in the Miscellaneous Options
menu is checked, events with Priority 1 through 5 start the On-Screen Code automatically.
4. Lamp Saver turned lamp off; lamp is cooling and will turn on at end of cooling period.
5. A Lamp On command from the remote control or via RS232 turns the lamp on.