Owner`s manual
Installation Preparation
18 VideoWallâ„¢/CineWallâ„¢ Installer/Integrator Manual
PRE
L
IMINAR
Y
3. Reinforce the bottom of the wall opening from behind with a 2x6 x 88.75 in. stud.
48.000" (1219.2 mm)
8.500"
(215.9 mm)
50.500" (1282.7 mm)22.500" (571.5 mm)
21.000"
(533.4 mm)
11.500"
(292.1 mm)
48.000" (1219.2 mm)
94.750" (2406.7 mm)
88.750" (2254.3 mm)
Reinforcing
studs,
2 x 6 x 73 in.
(2 per side)
Reinforcing
stud,
2 x 6 x 21 in.
(1 per side)
Support stud,
2 x 6 x 88.75 in.
Wall Opening Reinforcement - VideoWall VW-100HD
48.000" (1219.2 mm)
8.500"
(215.9 mm)
37.875" (962.0 mm)35.125" (892.2 mm)
33.625" (854.1 mm)
11.500"
(292.1 mm)
48.000" (1219.2 mm)
94.750" (2406.7 mm)
88.750" (2254.3 mm)
Reinforcing
studs,
2 x 6 x 73 in.
(2 per side)
Reinforcing
stud,
2 x 6 x 33.625 in.
(1 per side)
Support stud,
2 x 6 x 88.75 in.
Wall Opening Reinforcement - CineWall CW-95HD