Owner`s manual
Reference
VideoWallâ„¢/CineWallâ„¢ Installer/Integrator Manual 109
PRE
L
IMINAR
Y
Test Patterns: The VideoWall/CineWall has numerous internal test patterns that are
useful to technicians for advanced calibration, measurement and fault isolation purposes.
To access them, select
Test Patterns from the Diagnostics menu.
To select a test pattern, use the , , or buttons on the remote control unit to
highlight its name. Then, press ENTER.
To exit test pattern mode, select None and press ENTER.
Setup Summary: To see which input is currently active and a summary of settings
currently in effect for that input, select
Setup Summary from the Diagnostics menu.
Test Patterns
<ENTER> to select, None to show picture
None Red Red Scale Logo
White Green Green Scale Grid
Black Blue Blue Scale 4x4 Contrast
Gray Cyan Gray Scale Uniformity
Custom Color Yellow Colors Focus
Magenta Color Bars
Setup Summary
Current Setup Information
Source HDMI
Resolution 1920x1080
Scale/Jus tify 16x9 / Center
Position/Overscan 100,100 0%
Zoom UL/LR +1, +0 / -1, +2
Viewport UL/LR +0, +0 / +0, +0
Sharpness 7
Black Level (Offset) 52 50 104
White Level (Gain) 178 131 135
Group 0 Unit 0
White Balance (Gain) 100 100 100
Gray Balance (Offset) 7 7 7