User's Manual

V1.2 2020-09-25
www.risinghf.com
RHF0M0E5 User Manual
RisingHF
4
+MSG: Done
3.2 OTAA mode
Use the AT+ID command to query the module ID information and register the ID information to the
server OTAA mode device. Follow these steps to configure the node so that it can communicate with
the server.
3.2.1 ID query
Format
AT+ID
Return
+ID: DevAddr, 00:DF:E0:2E
+ID: DevEui, 20:4F:37:50:32:36:50:08
+ID: AppEui, 52:69:73:69:6E:67:48:46
3.2.2 Configure band
Set the band of the node according to the working frequency of the gateway.( EU868US915US915
HYBRIDCN779 EU433AU915AU915OLDCN470AS923KR920IN865 RU864
CN470PREQUELSTE920)
Format
AT+DR=CN470
Return
+DR: CN470
3.2.3 Configure channels
Set the channel of the node according to the type of gateway sub band
Format
AT+CH=NUM,0-7
Return
+CH: NUM, 0-7
Query whether the channel of the module matches the gateway through the AT+CH command
Format
AT+CH
Return
+CH: 8; 0,470300000,DR0,DR5; 1,470500000,DR0,DR5; 2,470700000,DR0,DR5;
3,470900000,DR0,DR5; 4,471100000,DR0,DR5; 5,471300000,DR0,DR5; 6,471500000,DR0,DR5;
7,471700000,DR0,DR5;
3.2.4 Configure mode
Format
AT+MODE=OTAA
Return
+MODE: LWOTAA