3. Installation
RuggedCom® RuggedSwitch® 19 RSG2288 Installation Guide Rev 108
3.2.3.1. AC Power Supply Wiring Examples
Figure 3.15. AC Single Power Supply Wiring Example
Figure 3.16. AC Dual Redundant
Power Supply Wiring Example
100-240VAC rated equipment: A 250VAC appropriately rated circuit breaker must
be installed.
Equipment must be installed according to the applicable country wiring codes.
When equipped with two HI voltage power supplies, independent AC sources can
be used to power the product for greater redundancy.
3.2.3.2. DC Power Supply Wiring Examples
+
Figure 3.17. DC Single Power Supply Wiring Example
+
+
Figure 3.18. DC Dual Redundant
Power Supply Wiring Example
125/250VDC rated equipment: A 300VDC appropriately rated circuit breaker must
be installed.