Specifications
55
Liebert FPC Related Products
Liebert FDC
F
its in the r
a
ck r
o
w to
provide power distribution
to individual racks when
u
sed with the Liebert FPC.
Liebert NX (40-120kVA)
The ne
w Li
e
be
r
t NX with
SoftScale™ UPS platform
can be sized to current
r
equirements and then
easily scaled as needs
c
h
ange.
Liebert Nform
A sim
p
le t
o u
s
e monitoring and
communications software solution
that combines network monitoring
o
f power and cooling equipment.
Installation And Service
Only Emerson can provide the
in
du
s
try’s largest, most experienced
service organization with a proactive
a
p
p
r
o
ach that prevents failures and
extends equipment life.
S
pecifications
Liebert FPC 15-125 kVA 150 kVA
User Interface
Display Type LCD LCD
A
udible Alarms Yes Yes
C
ommunications
C
ommunications Standard RS-422, RS-232 RS-422, RS-232
C
ommunications Options Liebert IntelliSlot Web/485 Card with Adapter, LDM Liebert IntelliSlot Web/485 Card with Adapter, LDM
En
vironmental
O
perating Temperature—Minimum 32° (0°C) 32° (0°C)
O
perating Temperature—Maximum 104°F (40°C) 104°F (40°C)
S
torage Temperature—Minimum -67°F (-55°C) -67°F (-55°C)
S
torage Temperature—Maximum 185°F (85°C) 185°F (85°C)
R
elative Humidity 0% to 95% without condensing 0% to 95% without condensing
Operating Elevation Up to 6,600 ft. (2,000m) Up to 6,600 ft. (2,000m)
Storage Elevation Up to 40,000 ft. (12,200m) Up to 40,000 ft. (12,200m)
Sound Emission/Audible Noise ANSI C89 ANSI C89
Heat Dissipation .73kW to 3.37kW 3.66kW
Cooling Convection Convection
P
hysical Data
Shi
pping Depth in(mm) 48 (1220) 70 (1778)
Shipping Height in(mm) 84 (2134) 84 (2134)
Shipping W
idth in(mm) 48 (1220) 54 (1372)
Shipping Weight lbs(kg) 1100 (499) to 1740 (789) 2630 (1193)
Unit Depth in(mm) 39.5 (1003) 39.5 (1003)
Unit Height in(mm) 78.5 (1994) 78.5 (1994)
Unit Width in(mm) 23.5 (597) 47 (1194)
Unit Weight lbs(kg) 1010 (458) to 1650 (748) 2490 (1129)
Color Black Black
Agency/Certification/Conformance
Safety UL 60950 UL 60950
ANSI, CSA, NEC, NEMA ANSI, CSA, NEC, NEMA
NFPA 75 NFPA 75
RFI/EMI FCC Part 15 EMI Class A FCC Part 15 EMI Class A
Transportation ISTA - Procedure 1H ISTA - Procedure 1H
Seismic None None
Options
Input Lightning/Surge Arrester Input Lightning/Surge Arrester
Output Surge Suppression Module Output Surge Suppression Module
Subfeed Output Circuit Breaker Subfeed Output Circuit Breaker
K-Rated Transformer K-Rated Transformer
Floor Pedestals Floor Pedestals
Liebert IntelliSlot Web/485 Card with Adapter Liebert IntelliSlot Web/485 Card with Adapter
Liebert Distribution Monitoring (LDM) Liebert Distribution Monitoring (LDM)
W
arr
an
t
y
S
tandard 1 year or 18 months after ship date 1 year or 18 months after ship date
Extended None None