Specifications

48
Liebert NX UPS with SoftScale
(40-120 kVA)
The ne
w Liebert NX UPS with SoftScale™ technology combines the industry’s
most flexible approach to scalability with an efficiency rating of up to 97%.
It is designed for small and medium size data centers that are facing
un
predictable changes in their IT systems.
The Liebert NX with SoftScale™ can be sized to current requirements and
then be easily scaled up in 20kVA increments. When an upgrade is
purchased an Emerson Customer Engineer will visit the site and install a
software key to complete the capacity upgrade. Modules can adapt from 40
kVA to 60 kVA to 80 kVA or from 80 kVA to 100 kVA to 120 kVA. In addition,
modules with identical or different ratings can work in parallel to handle
higher capacities.
These Liebert NX modules can be positioned in a row of racks alongside the
IT equipment it protects to optimize space utilization.
Liebert NX is
featured in these
Scenarios:
Scenario E
10-30 Racks
Three Phase
p
age 16
Scenario F
30-60 Racks
Three Phase
p
age 18
Features & Benefits
Flexibility:
n
Parallel units that are the
same or different capacities for greater
flexibility in managing power growth.
n
Generator compatible.
n
Power communications available
through Liebert IntelliSlot
®
Web Card
LB and Liebert MultiLink
shutdown
software.
n
Large and user-friendly LCD
d
is
p
l
ay provides operating information
in t
welve languages.
n
Internal automatic bypass
transfers load to bypass in the unlikely
e
v
e
n
t th
a
t a fault occurs in the UPS.
Optional wrap-around maintenance
allows the UPS to be powered down or
taken out of service without
disconnecting power to the load.
n
Easy servicing due to front accessibility
o
f cr
iti
cal components, self-diagnostics
and various monitoring options.
Lowest Total Cost Of Ownership:
n
Soft-switching technology optimizes
operation with the same high efficiency
at 40% utilization as at 100% utilization.
n
Adaptive input voltage window results
in fewer hits on the battery.
n
The unit’s compact footprint requires
less floor space, leaving you with more
room for other equipment.
n
Temperature-compensated battery
c
h
ar
gin
g extends
ba
ttery life.
Higher Availability:
n
Wider input voltage window and
frequency tolerances help to minimize
transfer to battery, reducing the
number of charging and discharging
cycles.
n
High overload rating capable of
clearing a 20 A branch circuit breaker.
n
Integrated ground fault detection
allows for effective transformerless
de
si
gn
, saving space and lowering the
weight.
n
True on-line double conversion
technology protects and conditions
a
g
ains
t the f
ull range of power
irregularities, requiring fewer transfers
t
o ba
tt
ery.
n
Advanced inverter control technology
provides the highest output power
quality to maximize efficiency and
o
perating life of connected equipment.
n
Load Bus Synchronization provides the
capability to synchronize the outputs
o
f t
w
o in
de
pe
ndent UPS modules
when they are configured as a
redundant system feeding
independent distribution paths.
n
An in
t
e
lli
gent battery management
algorithm monitors the battery to
de
t
ect any premature battery failure.