Specifications
14
Specifications Sceanrio D
Input Power 208V/120V - 3 phase
Raised Floor No
kW Range 8 - 24 kW
Racks 7 - 10
UPS
Liebert NX On-line
P
ower Distribution
- P
anelboards Liebert NX Slimline
- P
ower strips Liebert MP Advanced Power Strips
- Main
tenance Bypass Included in UPS
C
ooling Liebert Challenger 3000
M
onitoring Liebert Nform
Server Shutdown Liebert MultiLink
Surg
e Suppression Liebert AccuVar
Pr
oducts:
Knurr Rack
– Lightweight, modular racks that offer 83%
ventilation and simple add-on options.
Knurr Cable Management – A full line of cable management
accessories for effective control of any cabling requirements.
Liebert MP Advanced Power Strip – Designed to distribute
and manage power within the rack and meet the
requirements of any rack-mounted IT equipment.
Liebert NX UPS – A compact three-phase true on-line UPS
that offers power-factor correction, frequency conversion,
internal dynamic bypass, internal maintenance bypass switch,
internal batteries, additional battery cabinets, intelligent local
monitoring and remote communications.
Liebert NX SlimLine Power Distribution – A compact power
distribution unit integrated into the Liebert NX UPS that
provides power distribution to the individual racks.
Liebert AccuVar Surge Suppressor – Provides unparalleled
protection from transient surges and electrical line noise.
Liebert Challenger 3000 Precision Cooling – An active
precision cooling system providing a versatile and quiet room
solution, including temperature, humidity, filtration and
airflow in an extremely small footprint (< 9sq.ft.).
Liebert Nform Monitoring Software – Network-based
monitoring of alarm notifications from cooling and power
equipment.
Liebert MultiLink Shutdown Software – Automated
shutdown software permits configurable responses to UPS
status changes.
Installation & Support Services – Utilize Liebert’s local
expertise to assist in assembling turnkey installation services
as well as world-class service contracts for all of Liebert’s
power and cooling products.
Scenario D
7-10 Racks — Small Data Center
Three Phase
This is an e
xample of a recommended solution:
For more detailed
inf
o
r
mation about the
Liebert products in this
Scenario, go to the
p
a
g
e
s in
d
icated.
Kn
urr R
acks
page 20
Solution:
For the server room or small data center of 7–10 racks, this
innovative and reliable Liebert solution is perfect for your needs.
When information is critical and downtime inexcusable, this
pre-engineered solution has the reliability you demand. Racks,
managed power strips, precision cooling, uninterruptible power
and power distribution, surge suppression, monitoring, server
shutdown software, installation service and support –
all pre-engineered to work together.
Us
e this suggested scenario to begin framing the protection that
suits your needs. To configure a solution, contact your local
Liebert representative or call 1-800-877-9222.