Specifications
10
Scenario B
1-2 Racks — Network Access Closet
Single Phase
Specifications Scenario B (Option 1)
Input Power 208 / 120V - 1 phase
Raised Floor No
kW R
ange up to 1.8 kW
R
acks 1
UPS
Liebert GXT On-line
P
ower Distribution Liebert MP Advanced Power Strips
C
ooling Liebert MCR
M
onitoring Liebert Nform
Se
rver Shutdown Liebert MultiLink
Surg
e Suppression -
This is an example of a recommended solution:
Pr
oducts (Option 1):
Liebert MCR Integrated Enclosure
– An integrated rack
and enclosure with active precision cooling designed to
e
nsure the long-term viability of IT equipment.
Liebert MP Advanced Power Strip – Designed to
distribute and manage power within the rack and meet the
r
equirements of any rack-mounted IT equipment.
Liebert GXT UPS – A rack-mounted single-phase true
on-line UPS that offers power-factor correction, frequency
c
onversion, internal batteries, additional battery cabinets,
internal dynamic bypass and remote communications.
Liebert Nform Monitoring Software – Network-based
monitoring of alarm notifications from cooling and power
equipment.
Liebert MultiLink Shutdown Software – Automated
shutdown software permits configurable responses to
UPS status changes.
Installation & Support Services – Utilize Liebert’s local
expertise to assist in assembling turnkey installation
services as well as world-class service contracts for all of
Liebert’s power and cooling products.
Products (Option 2):
Liebert XDF Integrated Enclosure
– An integrated rack
and enclosure with active precision cooling designed to
ensure the long-term viability of IT equipment.
Liebert MP Advanced Power Strip – Designed to
distribute and manage power within the rack and meet the
requirements of any rack-mounted IT equipment.
Liebert GXT UPS – A rack-mounted single-phase true on-
line UPS that offers power-factor correction, frequency
conversion, internal batteries, additional battery cabinets,
internal dynamic bypass and remote communications.
Liebert Nform Monitoring Software – Network-based
monitoring of alarm notifications from cooling and power
eq
ui
pment.
Liebert MultiLink Shutdown Software – Automated
software for orderly shutdown of servers based on
c
onfigurable responses from UPS.
Installation & Support Services – Utilize Liebert’s local
expertise to assist in assembling turnkey installation
services as well as world-class service contracts for all of
Liebert’s power and cooling products.
For more detailed
inf
o
r
mation about the
Liebert products in this
Scenario, go to the
p
a
g
e
s in
d
icated.
Liebert MP
A
dvanced
Power Strip
page 56
Liebert
MCR
page 26
Specifications Scenario B (Option 2)
In
put Power 208 / 120V - 1 phase
Raised Floor No
kW Range up to 14 kW
Racks 1-2
UPS Liebert GXT On-line
Power Distribution Liebert MP Advanced Power Strips
Cooling Liebert XDF
Monitoring Liebert Nform
Server Shutdown Liebert MultiLink
Surge Suppression -
Solution:
A cost effective, integrated enclosure with self-contained
precision cooling, uninterruptible power, managed power strips,
monitoring, server shutdown software, installation service and
support – this solution allows for easy implementation of your
c
oolin
g r
eq
uirements by integrating active precision cooling into
the rack – all pre-engineered to work together
U
s
e this su
ggested scenario to begin framing the protection that
suits y
o
ur needs. T
o c
on
fi
gur
e a solution, contact your local
Liebert representative or call 1-800-877-9222.