Solutions For Business-Critical Continuity™ Liebert Integrated, Pre-Engineered Solutions Complete Protection For Network Servers and Data Centers
Table Of Contents Introduction Solution Scenarios Bringing Market-Leading Data Center Technology To Your Business A Total Solution. A Single Source.
For more than 40 years, Liebert has been the global leader in the world of business-critical systems. The best run companies have relied on Liebert products, technologies and services to provide the flexibility and availability they’ve needed to succeed. Today, we are solely dedicated to rapidly delivering the right solutions for your individual mission-critical applications. Integrated solutions. Pre-engineered benefits.
A Total Solution. A Single Source. Our pre-engineered solutions How is this possible? promise you flexibility and availability, which equates to the lowest cost of ownership. and successful legacy of protecting the operation of mission-critical With the widest range of products in the marketplace, we can provide maximum flexibility to meet your most stringent demands. We’re a single, global source with a long systems.
Liebert Solutions give your missioncritical network the flexibility to deal with uncertainty. Knowing what is happening with your critical power and cooling equipment—and having automated processes to shut down servers in an orderly way if required—is vital to system reliability and uptime. MONITORING Lightweight extruded aluminum frames with modular Racks Status Indicators SiteNet Integrator Silence 1 2 3 Output Relays 1 2 construction offer easy mounting for all IT equipment.
Glossary Of Terms Adaptive Architecture Industry Terms Power Cooling Liebert Adaptive Architecture Liebert Adaptive Architecture is a family of products and technologies that demonstrate the ultimate in flexibility while balancing the importance of minimal TCO and high availability. Power – Three Phase A three phase circuit consists of three phases, ground and in some cases neutral. Typical three phase voltages are 208V, 480V and 600V.
System Sizing Sizing a critical power system to meet present and future needsis a fundamental requirement. Present Requirements Estimating the present system size in kilovolt amperes (kVA) is done in a number of ways. Typical sources include computer site planning manuals, equipment nameplate data, and electrical service data.
Scenario A 1-2 Racks — Network Access Closet Single Phase This is an example of a recommended solution: Specifications Scenario A Input Power Raised Floor kW Range Racks UPS Power Distribution Cooling Monitoring Server Shutdown Surge Suppression 120V - 1 phase No 1 - 3 kW 1-2 Liebert PowerSure PSI Line-Interactive Liebert MP Advanced Power Strips Liebert Nform Liebert MultiLink - Solution: For the room in need of a single rack, this is an example of the Liebert solution you’ll need to protect your IT e
Scenario A Knurr Miracel® Rack Liebert PowerSure PSI UPS Liebert PowerSure PSI UPS page 34 Liebert XDA Airflow Enhancer Liebert MP Advanced Power Strip Liebert Monitoring & Shutdown page 80 Installation, Support and Services page 94 9
Scenario B 1-2 Racks — Network Access Closet Single Phase This is an example of a recommended solution: Specifications Scenario B (Option 1) Input Power Raised Floor kW Range Racks UPS Power Distribution Cooling Monitoring Server Shutdown Surge Suppression 208 / 120V - 1 phase No up to 1.
Scenario B Liebert MP Advanced Power Strip Option 1: Option 2: Liebert MCR enclosure with integrated cooling Liebert GXT UPS Liebert GXT UPS page 38 Liebert XDF page 30 Liebert Monitoring & Shutdown page 80 Liebert XDF enclosure with integrated cooling Liebert GXT UPS Installation, Support and Services page 92 11
Scenario C 3-6 Racks — Small Data Room Single Phase This is an example of a recommended solution: Specifications Scenario C Input Power Raised Floor kW Range Racks UPS Power Distribution - Power strips - Maintenance Bypass Cooling Monitoring Server Shutdown Surge Suppression 208 / 120V - 1 phase No 7 - 16 kW 3-6 Liebert GXT On-line Liebert MP Advanced Power Strips Liebert MicroPOD Liebert Challenger 3000 Liebert Nform Liebert MultiLink - Solution: For the room with 3–6 racks, this Liebert solution prot
Scenario C Liebert MicroPOD Liebert Challenger 3000 Cooling Liebert GXT UPS Knurr Miracel® Racks Liebert GXT UPS page 38 Liebert MicroPOD Liebert Challenger 3000 Cooling page 68 Liebert Monitoring & Shutdown page 80 Installation, Support and Services page 92 13
Scenario D 7-10 Racks — Small Data Center Three Phase This is an example of a recommended solution: Specifications Sceanrio D Input Power Raised Floor kW Range Racks UPS Power Distribution - Panelboards - Power strips - Maintenance Bypass Cooling Monitoring Server Shutdown Surge Suppression 208V/120V - 3 phase No 8 - 24 kW 7 - 10 Liebert NX On-line Liebert NX Slimline Liebert MP Advanced Power Strips Included in UPS Liebert Challenger 3000 Liebert Nform Liebert MultiLink Liebert AccuVar Solution: For t
Scenario D Knurr Miracel® Racks Liebert Challenger 3000 Cooling Liebert Challenger 3000 Cooling SlimLine Distribution Cabinets Liebert NX UPS Liebert MP Advanced Power Strip Knurr Miracel® Racks Liebert NX UPS page 44 NX SlimLine Power Distribution Liebert AccuVar page 64 Liebert Challenger 3000 Cooling page 64 Liebert Monitoring & Shutdown page 80 Installation, Support and Services page 92 15
Scenario E 10-30 Racks — Small Data Center Three Phase This is an example of a recommended solution: Specifications Sceanrio E Input Power Raised Floor kW Range Racks UPS Power Distribution - Panel boards - Power strips - Maintenance Bypass Cooling Monitoring Server Shutdown Surge Suppression 480 / 208V - 3 phase Optional 36 - 72 kW 10 - 30 Liebert NX On-line Liebert FPC Liebert MP Advanced Power Strips Included in UPS Liebert DS Liebert Nform Liebert MultiLink Liebert AccuVar Solution: As your system
Liebert DS Cooling Scenario E Liebert NX UPS Liebert FPC Power Distribution Liebert NX Battery Cabinet Knurr Miracel® Racks Liebert DS Cooling Liebert NX UPS page 48 Liebert FPC Power Distribution page 52 Liebert AccuVar page 64 Liebert DS Cooling page 68 Liebert Monitoring & Shutdown page 80 Installation, Support and Services page 92 17
Scenario F 30-60 Racks — Medium Data Center Three Phase This is an example of a recommended solution: Specifications Sceanrio F Input Power Raised Floor kW Range Racks UPS Power Distribution - Panelboards - Power strips - Maintenance Bypass Cooling - Room - High Density (Top of Rack) - High Density (in-line) - High Density Refrigerant Chiller Monitoring Server Shutdown Surge Suppression 480 / 208V - 3 phase Optional 72 - 144 kW 30 - 60 Liebert NX On-line Liebert FPC Liebert MP Advanced Power Strips Incl
Scenario F Liebert DS Cooling Liebert XDH Liebert XDC Knurr Miracel® Racks Liebert FPC Power Distribution Liebert NX Battery Cabinet Liebert NX UPS Liebert XDV Liebert FPC Power Distribution Liebert NX Battery Cabinet Liebert NX UPS Liebert Paralleling Cabinet Liebert AccuVar page 64 Liebert DS Cooling page 68 Liebert XDC page 74 Liebert XDH page 78 Liebert XDV page 76 Liebert Monitoring & Shutdown page 80 Installation, Support and Services page 92 19
Knurr Miracel Server Rack ® Knurr Server Racks Scenario A are featured in 1-2 Rack these Scenarios: Single Phase page 8 Scenario C Scenario D Scenario E Scenario F 3-6 Racks Single Phase page 12 7-10 Racks Three Phase page 14 10-30 Racks Three Phase page 16 30-60 Racks Three Phase page 18 This unique, modular construction allows for flexible mounting of accessories, as well as a complete cable management system with an extensive range of accessory components.
Frequently Asked Questions Question Resolution Your cabinet frame is manufactured from aluminum. Is that strong enough for a server cabinet? Many high load products are made from aluminum, because it offers a significantly lower product weight in tandem with a stiff, strong frame. These products include airplanes, automobiles and spacecraft. Aluminum performs very well in high weight load applications. I have been using the same cabinet manufacturer for the past few years.
Knurr Miracel® Server Rack Specifications ENCLOSURE DIMENSIONS Overall Frame Dimensions 42U Model Rack Width Depth Internal Rack Width IT Component Width In. (mm) In. (mm) In. (mm) In. (mm) Adjustable Rack Depth Max In.(mm) Internal Rack Height RACK UNITS Side Panel In. (mm) 010200012 23.6 (600) 39.3 (1000) 21.1 (535) 17.8 (450) 36.8 (935) 42 73.5 (1867) No 010200013 23.6 (600) 39.3 (1000) 21.1 (535) 17.8 (450) 36.8 (935) 42 73.5 (1867) Yes 002185450 23.6 (600) 43.
Knurr Miracel Related Products Liebert OpenComms EM and Liebert OpenComms vEM-14 Controllers Liebert OpenComms EM controllers are network-enabled devices for monitoring temperature, humidity and contact closures inside critical environments, including racks and small computer rooms. Liebert PowerSure PSI The most price competitive UPS in its class with a factory-installed Liebert IntelliSlot Web Card for network communications. Available in 1000, 1440, 1920, 2200 and 3000 VA ratings.
Knurr Accessories are featured in these Scenarios: Knurr Accessories Scenario A Scenario C Scenario D Scenario E Scenario F 1-2 Rack Single Phase page 8 3-6 Racks Single Phase page 12 7-10 Racks Three Phase page 14 10-30 Racks Three Phase page 16 30-60 Racks Three Phase page 18 Knurr Miracel® Side Panel Material: Sheet steel, 1.0 mm Finish/Color: Powder-coated texture, black Supply Schedule: 1 side panel & mounting material Supplied: Flat packed kit Depth Height In. (mm) In.
Knurr Miracel® Casters Can be mounted on the threaded eyelet of the basic rack. Caster Diameter: 2.95” (75 mm) Threaded Bolt: M12 Loaded Capacity Per Caster: 220 lbs Supply Schedule: 2 Casters swivel locking, 2 Casters swivel non locking, 4 Casters brackets Supplied: Flat packed kit Height Order Number Up 01.350.615.9 1 unit In. (mm) 4.31” (109.5) Cable Management — Lobster Claw Easy to install cable management piece that holds bundles of cable for efficient routing in the cabinet.
Liebert Foundation Scenario B MCR is featured in 1-2 Racks this Scenario: Single Phase Liebert MCR Mini Computer Room page 10 The Liebert Foundation MCR is a self-contained rack enclosure system that includes a load-sized, precision cooling unit located at the bottom of the enclosure, with the option of a top mount design, supplying cool air to sensitive equipment on all levels. A back-up cooling system ensures environmental security.
Frequently Asked Questions Question Resolution Can’t I just buy a cabinet and put in an air conditioner? The Liebert Foundation MCR provides a complete solution. There is no need to purchase and install separate add-on components. The Liebert Foundation MCR is a self-contained system ready to go right from the start with components that are specifically designed to work together.
Liebert MCR Mini Computer Room Specifications ENCLOSURE DIMENSIONS Overall Frame Dimensions Model Height* Rack Width** Depth*** In. (mm) Width Adjustable Rack Depth Available Width B**** Internal Rack Height In. (mm) In. (mm) Max In.(mm) Min In.(mm) RACK U In. (mm) HD_780 77 (1956) 23.5 (597) 30 (762) 19 (483) 17.8 (450) 22.5 (571.5) 18.5 (470) 42 73.5 (1867) HD_788 77 (1956) 23.5 (597) 38 (965) 19 (483) 17.8 (450) 30.5 (775) 26.5 (673) 42 73.
Liebert MCR Mini Computer Room Related Products Liebert OpenComms EM and Liebert OpenComms vEM-14 Controllers Liebert OpenComms EM controllers are network-enabled devices for monitoring temperature, humidity and contact closures inside critical environments, including racks and small computer rooms. Liebert PowerSure PSI The most price competitive UPS in its class with a factory-installed Liebert IntelliSlot web card for network communications. Available in 1000, 1440, 1920, 2200 and 3000 VA ratings.
Liebert XDF is featured in this Scenario: Liebert XDF Scenario B 1-2 Racks Single Phase page 10 Liebert XDF is a secured enclosure with integrated high heat density cooling, providing the benefits of big room support in a cost-effective package.
Liebert XDF Features & Benefits Feature: Flexibility: Higher Availability: Lowest Total Cost Of Ownership: n n n n Standard integrated unit includes rack with extreme density cooling system with built-in monitoring and control All integrated cooling, power, monitoring and other accessories are designed for optimum compatibility and factory tested to ensure operational integrity upon installation.
Liebert XDF Systems Competitive Comparison Feature Liebert XDF Liebert Advantages Complete, self- contained unit Includes rack, cooling, monitoring and control. The self-contained Liebert unit provides plug-and-play installation with no on-site assembly or mechanical connections required. Cooling method Three options: 1. Self-contained air cooled 2. Air cooled with remote condenser. 3. Water/ glycol-cooled.
Specifications Liebert XDF Height, In. (mm) Overall Cabinet Only Fan Guard Equipment Rack Area Width, In. (mm) Overall EIA Nominal Inside Dimension Depth, In. (mm) Overall Mounting Depth, adjustable, minimum Mounting Depth, adjustable, maximum Weight, Lb (kg) Cabinet Only Equipment Capacity Electrical Data Control & Fan Supply Voltage Ph Hz Unit FLA Max Fuse or Circuit Breaker Amps Min.
Liebert PowerSure PSI is featured in this Scenario: Liebert PowerSure PSI UPS Scenario A 1-2 Racks Single Phase page 8 Liebert PowerSure PSI UPS offers an unbeatable combination of features and value in only 2U of rack space. The unit is rack/tower configurable, and has options for extended battery time and communication/shutdown. The PowerSure PSI is also available with factory installed Web/SNMP Card in the PowerSure PSI “w” models.
Competitive Comparison The Liebert PowerSure PSI can be ordered network-enabled from the factory with the Liebert IntelliSlot Web Card installed for SNMP communications. This option makes the Liebert PowerSure PSI Network Solution Package the most competitively priced UPS on the market when compared to similar products. Plus, you can add extended battery backup without replacing the existing unit with a larger model.
Liebert PowerSure PSI UPS Specifications PS1000RT2-120 Model Number Model Number with Liebert IntelliSlot PS1000RT2-120W Web/SNMP Card Installed 1000VA/750W Power Rating, VA/W Dimensions, W x D x H, in (mm) Unit 3.43 x 22 x 17 (87 x 557 x 430) Weight, lbs (kg) Unit 61.7(28.0) Input AC Parameters Surge Protection Voltage Range Without Battery Operation Frequency Range Input Power Cord 10 ft.
Liebert PowerSure PSI Related Products Mounting Kits Rack slide kits, wall mount bracket kits and telecom/relay rack shelves are available for use with the Liebert PowerSure PSI. Liebert MicroPOD™ Maintenance bypass switch that permits scheduled maintenance or UPS replacement without discontinuing power to critical equipment. Liebert Nform A simple to use monitoring and communications softwaresolution that combines network monitoring of power and cooling equipment.
Liebert GXT is featured in these Scenarios: Liebert GXT UPS Scenario B 1-2 Racks Single Phase page 10 Scenario C 3-6 Racks Single Phase page 12 Liebert GXT UPS leads the industry in combining the best total cost of ownership with small size, high capacity and function-rich features. This true online UPS offers internal batteries, unlimited extended external batteries, and internal bypass capability, resulting in continuous uptime for the connected equipment.
Competitive Comparison The Liebert GXT offers a number of advantages over the competition, which you can use to generate new high-margin sales. Feature Liebert GXT APC SmartUPS-RT Powerware 9125 Tripplite Smart Online Capacity range down to 500VA. Yes No No No Widest input frequency window (40-70Hz). Yes No No No Delivered fully assembled — batteries connected and activated at the factory. Yes No No Yes Standard rack ears and tower pedestal.
Liebert GXT UPS Specifications Model Number GXT2-500RT120 GXT2-700RT120 GXT2-1000RT120 Model Rating VA/W 500VA/350W 700VA/ 490W 1000VA / 700W 1500VA / 1050W Dimensions: in (mm) 3.5 x 21.5 x 17 in. 3.5 x 21.5 x 17 in. 3.5 x 21.5 x 17 in. 3.5 x 21.5 x 17 in. (89 x 546 x 432 mm) (89 x 546 x 432 mm) (89 x 546 x 432 mm) (89 x 546 x 432 mm) 49 lbs. (22 kg) 49 lbs. (22 kg) 50 lbs. (23 kg) 51 lbs. (23 kg) WxDxH Weight: lbs.
Specifications Model Number Model Rating DIMENSIONS Unit W x D x H in. (mm) WEIGHT lbs (kg) Unit GXT2-6000RT208 GXT2-10000RT208 4200W/5200VA at 120/208 (120 or 240 degrees) 8000W/8660VA at 120/208 (120 or 240 degrees) 4200W/6000VA at 120/240 (180 degrees) 8000W/10000VA at 120/240 (180 degrees) 6.9 x 24.2 x 16.9 (176 x 615 x 430) 10.5 x 26.0 x 16.9 (267 x 660 x 430) 67 (30.3) 109 (49.
Liebert GXT UPS Specifications POWER DISTRIBUTION GXT 2-6000RT208 Model Number PD-HDWR PD-HDWR-MBS PD-001 Amp Rating 30 No Bypass 30 With Bypass 30 With Bypass Input Power Connection Hardwire Terminals Hardwire Terminals L14-30P PD-002 PD-003 30 With Bypass 30 With Bypass L14-30P L14-30P PD-004 PD-005 30 With Bypass 30 With Bypass L14-30P L14-30P PD-006 PD-007 GXT 2-6000RTL630 Model Number PD-L630 GXT 2-10000RT208 Model Number PD-101 PD-102 PD-103 PD-104 PD-105 30 With Bypass 30 With Bypass L14-
Liebert GXT Related Products Rack-Mounting Kits These kits are required to mount a Liebert GXT and external battery cabinets within equipment racks. Liebert MicroPOD™ A maintenance bypass switch that permits scheduled maintenance or UPS replacement without discontinuing power to critical equipment. Liebert Nform A simple to use monitoring and communications softwaresolution that combines network monitoring of power and cooling equipment.
Liebert NX is featured in this Scenario: Liebert NX UPS (10-30 kVA) Scenario D 7-10 Racks Three Phase page 14 The Liebert NX is a true on-line, double conversion, mid-sized, three-phase UPS system that delivers complete, centralized power protection for missioncritical systems.
Frequently Asked Questions Question Resolution Besides providing backup when the electricity goes out, does the Liebert NX take care of all power problems? Yes. It utilizes true on-line double conversion technology that corrects all types of power fluctuations. Is it more expensive to operate than several UPS systems? The Liebert NX actually offers a lower total cost of ownership than many smaller UPS units.
Liebert NX UPS (10-30 kVA) Liebert NX Bundles Liebert NX UPS General Description Quantity of Liebert NX UPS* kVA/kWatts External Battery Cabinet SNMP Card ø System Paralleling Cabient § 38SB030C0CHR √ Parallel UPS system rated 30kVA to 90kVA redundant, 208/120V input, 208/120V output 1 to 4 30/24 to 90/72 Redundant 38BP030RHR1BNS IS-WEBLB 38SC030CC64UR0T 38SB020C0CHR √ Parallel UPS system rated 20kVA to 60kVA redundant, 208/120V input, 208/120V output 1 to 4 20/16 to 60/48 Redundant 38BP0
Specifications Models NX 10 kVA NX 15 kVA NX 20 kVA NX 30 kVA Power Rating - kVA 10 15 20 30 8 12 16 24 Power Rating - kW Input AC Specifications Phase 3 Power Factor 0.
Liebert NX UPS with SoftScale™ (40-120 kVA) Liebert NX is featured in these Scenarios: Scenario E 10-30 Racks Three Phase page 16 Scenario F 30-60 Racks Three Phase page 18 The new Liebert NX UPS with SoftScale™ technology combines the industry’s most flexible approach to scalability with an efficiency rating of up to 97%. It is designed for small and medium size data centers that are facing unpredictable changes in their IT systems.
Frequently Asked Questions Question Response What are the advantages of the Liebert NX with SoftScale compared to similar capacity UPS systems? Here are some important differences: Parallel units for added capacity as your needs grow. Complete Power Conditioning — True online double conversion technology corrects all types of power fluctuations. Save On Energy Usage — The Liebert NX offers improved efficiency up to 97%, which results in lower operating costs.
Liebert NX UPS with SoftScale™ (40-120 kVA) Liebert NX Bundles Liebert NX UPS General Description Quantity of Liebert NX UPS kVA/Watts External Battery Cabinet SNMP Card System Paralleling Cabient Paralleling Cable 38SB080A0A00 ü√ Parallel UPS system rated 40kVA to 240kVA redundant 1 to 4 40/36 to 240/216 Redundant. 38BP080XMR1BNS √ OCWEB-LB 38SC080AA64KB0S 531614-10 ü 38SB080A0A00 ü √ Parallel UPS system rated 80kVA to 360kVA redundant 1 to 4 480/72 to 360/324 Redundant.
Specifications Models Power Rating - kVA Power Rating - kW Input AC Specifications Phase Power Factor Frequency - Hz Input Voltage Input Voltage Range General Specifications UPS Technology Battery Specifications Battery Test Type Battery Technology Output AC Specifications Nominal Voltage Frequency - Hz Output Waveform Panelboards or Receptacles User Interface LCD Display Communications Communications Options NX 40 kVA 40 36 TM NX 80 kVA 80 72 NX 100 kVA 100 90 NX 120 kVA 120 108 3 > 0.
Liebert FPC Power Distribution Unit Liebert FPC is featured in these Scenarios: Scenario E 10-30 Racks Three Phase page 16 Scenario F 30-60 Racks Three Phase page 18 The rack-size Liebert FPC provides higher quality, more flexible power distribution for high-density data centers. It is engineered to combine the convenience and cost savings of a pre-packaged, factory-tested unit with the flexibility of a customtailored power system.
Frequently Asked Questions Question Resolution Why do I need a product like this in my data center? As your rack-mount systems grow in number, complexity and criticality — so must your power distribution system. Creating high quality power is a major step towards protecting the operation of a critical facility.
Liebert FPC Power Distribution Unit Competitive Comparison Feature Liebert FPC APC InfraStruXure PDI Powerpack PDU MGE Power Management Module United Power PDM The Liebert Advantage Monitoring Local and remote monitoring is standard. Liebert Distribution Monitoring (optional) can adapt monitoring to include any combination of panelboard main breaker, branch breaker, sub-feed breakers and / or output breaker.
Specifications Liebert FPC User Interface Display Type Audible Alarms Communications Communications Standard Communications Options Environmental Operating Temperature—Minimum Operating Temperature—Maximum Storage Temperature—Minimum Storage Temperature—Maximum Relative Humidity Operating Elevation Storage Elevation Sound Emission/Audible Noise Heat Dissipation Cooling Physical Data Shipping Depth in(mm) Shipping Height in(mm) Shipping Width in(mm) Shipping Weight lbs(kg) Unit Depth in(mm) Unit Height in(mm
® Liebert MP Advanced Power Strips Liebert MP is featured in these Scenarios: Scenario A Scenario B Scenario C Scenario D Scenario E Scenario F 1-2 Racks Single Phase page 8 1-2 Racks Single Phase page 10 3-6 Racks Single Phase page 12 7-10 Racks Three Phase page 14 10-30 Racks Three Phase page 16 30-60 Racks Three Phase page 18 Liebert MP Advanced Power Strips are designed to distribute and manage power within network cabinets and server racks.
Competitive Comparison Feature Liebert MP Advanced Power Strips APC Geist Power Readings Current, Voltage & Power Current Only Current Only Switched Receptacles Yes Yes Not Available Zero U Models 120/208 VAC20/30 AMP 21 Receptacles 208V 3PH 24 Receptacles 120/208 VAC 20 AMP 16 Receptacles 208V 3PH 24 Receptacles Single Phase 120/208 VAC 24 Receptacles 3PH 120/208 VAC 24 Receptacles Rackmount Models 120/208 VAC 20/30 AMP 18 Receptacles 120/208 VAC 20/30 AMP 16 Receptacles 120/208 VAC 20/3
Liebert MP® Advanced Power Strips Specifications INPUT (Rated) Form Factor Connection(s) Voltage Current Phase Type OUTPUT (Rated) Quan Length Voltage Current Connection(s) Phase Type Quan Monitoring Liebert LCD/LED Part Number Liebert MP Advanced Power Strips (Monitoring) / MP-M Series Rckmnt / 1U 120 15 1PH 5-15P 1 6’ 120 15 1PH 5-15/20R 10 LCD MP-M5109 Rckmnt / 1U 120 20 1PH 5-20P 1 6’ 120 20 1PH 5-15/20R 10 LCD MP-M5110 Rckmnt / 1U 120 20 1PH L5-20P 1 6’
Liebert MP Strips Related Products Knurr Racks Complete line of racks and cabinets, featuring adjustable racks and rack rails, reversible quick release doors, improved cable management, easy access side panels and multiple door options. Liebert MCR Self-contained cabinet with cooling and options for power protection and management systems. Liebert XDF A secured enclosure with integrated high heat density cooling, providing the benefits of big room support in a costeffective package.
Liebert AccuVar is featured in these Scenarios: Liebert AccuVar Scenario D Scenario E Scenario F 7-10 Racks Three Phase page 14 10-30 Racks Three Phase page 16 30-60 Racks Three Phase page 18 The Liebert AccuVar Series is a multi-phase, multi-mode distribution panel mounted transient voltage surge suppressor (TVSS) that offers continuous protection from damaging transients and electrical line noise.
AccuVar TVSS Technical Specifications Maximum Continuous Operating Voltage (MCOV) 120V 125%, all others 115% Fault Current Rating (AIC) 200 kAIC Operating Frequency Range 47 – 63 Hz Connection Parallel (10-14 AWG) 50 EMI/RFI Attenuation 10 kHz-100MHz (60 dB – Optional) (60 dB – Optional) Response Time <0.
Precision Cooling Today’s computing technologies compound conventional cooling problems. Blade servers, communications switches and other electronics are being packed into tighter and tighter spaces. Computing capacity that once filled an entire room is now contained in a single rack — creating extreme power and heat densities.
Why Liebert Precision Cooling? We Surround You with Expertise From the first precision-cooling system in 1965, to the first enclosed protection system in 1994, to the first highdensity cooling system in 2002, Liebert has been the global leader in the world of business-critical systems. One of our most unique aspects is our network of local Liebert cooling experts, who offer Liebert cooling solutions tailored to your requirements.
Liebert Challenger 3000 Cooling Liebert Challenger is featured in these Scenarios: Scenario C Scenario D 3-6 Racks Single Phase page 12 7-10 Racks Three Phase page 14 Liebert Challenger 3000 precision air conditioning system provides complete environmental control, including precise temperature, humidity and air filtration. Designed to fit in the crowded confines of an equipment room or laboratory, it offers an extremely compact footprint for facilities where space is at a premium.
Frequently Asked Questions Question Resolution Why is a Liebert Challenger 3000 precision cooling system better than ordinary building air conditioning? The Liebert Challenger 3000 offers a much higher level of reliability compared to comfort cooling systems. It uses rugged refrigeration components that are designed to operate 24 hours a day, 365 days a year. The Liebert Challenger 3000 also provides the precise temperature and humidity control required by sensitive electronic computer equipment.
Liebert Challenger 3000 Cooling Specifications Liebert Challenger based refrigerant R-22 System Type BU= Up Flow w/o raised floor BF= Down Flow w/ raised floor o Indoor Unit ( based on 72 F, 45% RH) Net Capacity Data - Standard Air Volume Total Sensible Self-Contained Air Cooled BF/BU 042A BF/BU 067A BTU/H kW BTU/H kW 37,900 11.1 58,300 17.1 37,900 11.1 58,300 17.1 Indoor Cabinet Dimensions - Both 042A & 067A Unit Height, in (mm) Depth, in (mm) 76 (1930) 33.
Liebert Challenger Related Products Liebert Liqui-tect® Leak Detection Systems Provide quick sensing, accurate reporting and precise location of leaks below the floor or above the ceiling in critical facilities, allowing you to find and correct a leak before moisture can damage computers, wiring connections or other sensitive electronics. Liebert Universal Monitor This all-purpose, simple to use monitoring panel features multi-sensing, remote monitoring and remote control capabilities.
Liebert DS is featured in these Scenarios: Liebert DS Cooling Scenario E Scenario F 10-30 Racks Three Phase page 16 30-60 Racks Three Phase page 18 Liebert DS precision cooling system provides efficient, precise, reliable control of room temperature, humidity and airflow for proper operation of critical electronic equipment. The flexible Liebert DS offers high energy efficiency, user-friendly iCOM controls, modular frame, front service access, and compressor options.
Competitive Advantages You may be asked about the advantages of the Liebert DS cooling system compared to building air conditioning or other types of cooling systems. Here are some important differences that make the Liebert solution the right choice for many applications: Feature Wide Choice of Capacities Downflow models (for raised floor applications) from 35-105 kW (8-30 tons) capacities and upflow models (for non-raised floor applications) in 35-105 kW (8-12 tons) sizes.
Liebert DS Cooling Specifications Air-cooled capacity data - R-407C refrigerant Model Size (kW) 035 053 070 Compressor Size Digital Scroll Digital Scroll Digital Scroll Net capacity data kW (BTUH), standard air volume and evaporator fan motor 72˚F DB, 58.6˚F WB (22.2˚C DB, 14.8˚C WB) 45% RH Total kW (BTUH) 33.0 (112,700) 49.3 (168,400) 61.7 (210,600) Sensible kW (BTUH) 33.0 (112,700) 49.3 (168,400) 57.2 (195,100) Indoor Unit Dimensions, In (mm) Model No.
Liebert DS Related Products Liebert Liqui-tect® Leak Detection Systems Provide quick sensing, accurate reporting and precise location of leaks below the floor or above the ceiling in critical facilities, allowing you to find and correct a leak before moisture can damage computers, wiring connections or other sensitive electronics. Liebert Universal Monitor This all-purpose, simple to use monitoring panel features multisensing, remote monitoring and remote control capabilities.
Liebert XD Systems are featured in this Scenario: Liebert XD Systems Liebert XDC Liebert XDV Adding targeted cooling is more cost-efficient than trying to lower the temperature of localized hot spots by increasing the overall room air conditioning capacity. The Liebert XD solution for high heat density cooling applications is a hybrid approach using a combination of floor mount missioncritical cooling units and supplemental cooling from the Liebert XD Series.
Frequently Asked Questions Question Resolution I already have a cooling system. Why do I need XD? In many cases, high heat density hot spots or zones require targeted cooling solutions. The Liebert XD systems are specifically designed to address the higher heat loads that result from implementing blade servers or server consolidation strategies.
Liebert XDC is featured in this Scenario: Liebert XDC Coolant Chiller Scenario F 30-60 Racks Three Phase page 18 The Liebert XDC Coolant Chiller is a specially designed indoor unit that connects directly to Liebert XDH and Liebert XDV units, providing chilled pumped refrigerant circulation and control. The packaged unit includes Enclosure, Pumps, Heat Exchanger, Scroll Compressors, Receiver Tank, Controls, Valves and Piping.
Specifications LIEBERT XDC Nominal Capacity 60 Hz 160 kW / 46 Ton Nominal Capacity 50 Hz 130 kW / 37 Ton Input Voltage 460 V, 3 ph, 60 Hz 380/420 V, 3 ph, 50 Hz Full load amps 79 A Height 78” (1981 mm) Width 74” (1879 mm) Depth Weight, empty 34” (863 mm) 2000 lbs (907 kg) Liebert XDC Related Products Liebert Liqui-tect® Leak Detection Systems Provide quick sensing, accurate reporting and precise location of leaks below the floor or above the ceiling in critical facilities, allowing you to fin
Liebert XDV is featured in this Scenario: Liebert XDV Cooling Module Scenario F 30-60 Racks Three Phase page 18 The Liebert XDV Cooling Module mounts vertically above or on the IT rack enclosure, drawing hot air from inside the cabinet or from the hot aisle. It then cools the air and discharges it down to the cold aisle. This space saving solution requires zero floor space. Liebert XDV Features & Benefits Flexibility: Higher Availability: Lowest Total Cost Of Ownership: n Requires no floor space.
Specifications XDV10 Nominal Capacity, 60 Hz1 10 kW / 2.8 Ton Nominal Capacity, 50 Hz1 8 kW / 2.3 Ton Nominal Airflow, 60 Hz 1000 CFM (1700 m3/h) Nominal Airflow, 50 Hz 830 CFM (1410 m3/h) Input Voltage 120 V, 1 ph, 60 Hz 230 V, 1 ph, 50/60 Hz Full load amps 2A @ 120V, 1ph, 60 Hz 1A @ 230V, 1ph, 50 Hz Audible Noise, 60 Hz / 50 Hz 78 dBa / 73 dBa Sound Power Height, module only 14” (355 mm) Width 23” (581 mm) Depth 29.5”-39.
Liebert XDH is featured in this Scenario: Liebert XDH Cooling Module Scenario F 30-60 Racks Three Phase page 18 The modular Liebert XDH Horizontal Row Cooler is placed directly in line with rack enclosures. Air from the hot aisle is drawn in through the rear of the unit, cooled, and then discharged through the front of the unit into the cold aisle. The modular and adaptive design of the Liebert XDH allows it to be easily added as the demand for cooling increases.
Specifications Nominal Capacity, kW (Tons) XDH20 XDH32 22 (4.7) 30 (6.4) 208/ 1 / 60 Voltage/Phase/Frequency 220 / 1 / 60 120 / 1 / 60 Physical Data Height - Inches (mm) 78 (1981) Width - Inches (mm) 12 (305) Depth - Inches (mm) 42 (1067) Weight - lbs. (kg) 233 (106) 246 (112) Footprint Unit (sf) 3.5 Unit with Service Area 4.5 Warranty Unit Liebert Stand. Labor Liebert Stand. Parts Liebert Stand.
Liebert Nform Software Liebert Nform is featured in these Scenarios: Scenario A Scenario B Scenario C Scenario D Scenario E Scenario F 1-2 Racks Single Phase page 8 1-2 Racks Single Phase page 10 3-6 Racks Single Phase page 12 7-10 Racks Three Phase page 14 10-30 Racks Three Phase page 16 30-60 Racks Three Phase page 18 Liebert Nform is a network communications system that will enable you to leverage the distributed monitoring capabilities of your network connected equipment.
Features & Benefits continued Feature: Higher Availability: Flexibility: Lowest Total Cost Of Ownership: Device Surveillance Ensures the availability of each monitored piece of equipment by active monitor polling. As long as the device supports SNMP, the system can actively poll equipment and determine the online status. Some monitoring systems determine the availability of equipment by a simple ICMP ping.
Liebert Nform Software Frequently Asked Questions Question Resolution Can Liebert Nform shutdown operating systems when an alarm is received, as your Liebert MultiLink software does? Yes, by adding the Liebert MultiLink shutdown license, Liebert Nform can be setup to send shutdown commands to Liebert MultiLink 1.5 clients. If I am not using Liebert equipment, can I still use Nform? Yes. Liebert can custom build templates for your UPSs to work with Liebert Nform.
Liebert Nform Competitive Comparison Feature Liebert APC Lock Application Lets you select the alarm that you wish to delete, acknowledge it, close it using the tool bar ribbon buttons. Yes No Desktop View Provides a desktop overview of all managed devices. Users can quickly identify all devices operating normally, any present alarms and any devices not communicating properly. Yes No Notification Updates Users can quickly view the notifications on a device. This can be displayed per device.
Liebert Nform Software Specifications Software Options Liebert Nform Software Liebert Nform Software Liebert Nform Software **Download Edition Professional Edition Enterprise Edition 1 System Features Local Client Viewer 1 1 No No 5 Windows NT 4.0 w/SP6 or higher, Windows 2000, Windows XP, Windows 2003 Server Windows NT 4.0 w/SP6 or higher, Windows 2000, Windows XP, Windows 2003 Server Windows NT 4.
Liebert Nform Related Products Liebert IntelliSlot Webcard Delivers SNMP, Telnet and web-management capability for enhanced communications and control of Liebert UPS, Power Management or Precision Cooling systems. The card manages a wide range of operating parameters, alarms and notifications, transmitting data over the network. Liebert MP Advanced Power Strips “Smart” power strips allowing customers to monitor and control equipment at the receptacle level.
Liebert MultiLinkTM Automated Shutdown Software Liebert MultiLink is featured in these Scenarios: Scenario A Scenario B Scenario C Scenario D Scenario E Scenario F 1-2 Racks Single Phase page 8 1-2 Racks Single Phase page 10 3-6 Racks Single Phase page 12 7-10 Racks Three Phase page 14 10-30 Racks Three Phase page 16 30-60 Racks Three Phase page 18 Liebert MultiLink is the perfect complement to a Liebert UPS system, preventing unexpected server shutdowns and minimizing downtime.
Competitive Comparison Liebert MultiLink PowerWare LanSafe5 APC PowerChute Business Edition MGE Power Management Module Type of Monitoring Connection Serial, Contact Closure, SNMP Serial, Contact Closure, SNMP Serial, Contact Closure, SNMP Serial, Contact Closure, SNMP E-Mail Notification Yes Yes Yes Yes Paging Notification Yes Yes Yes Yes Configurable Alarm Text Messages Yes Yes Yes Yes Multiple Computer Automated Shutdown Yes Yes Yes Yes Feature 87
Liebert MultiLink Automated Shutdown Software Specifications MultiLink 1.5 System Features Multilink Fundamental Multilink Advanced Version 3.6 Version 3.
Liebert MultiLink Related Products Liebert MultiPort4 Relay contact multiplexing unit communicates the On Battery and Low Battery status of a single UPS to connected PCs, servers, or workstations. The user-installable, hot-swappable card provides UPS communications to a host computer and up to four additional computer systems with the Liebert IntelliRack multiplexing unit or UPS systems equipped with the Liebert Intellislot communication port.
Liebert IntelliSlot Web Card Liebert IntelliSlot Web Card is featured in these Scenarios: Scenario A Scenario B Scenario C Scenario D Scenario E Scenario F 1-2 Racks Single Phase page 8 1-2 Racks Single Phase page 10 3-6 Racks Single Phase page 12 7-10 Racks Three Phase page 14 10-30 Racks Three Phase page 16 30-60 Racks Three Phase page 18 Liebert IntelliSlot Web Card (formerly Liebert OpenComms Web Card and Liebert OpenComms NIC Card) delivers SNMP and Web management to a Liebert UPS, Power
Competitive Comparison - Network Card Comparison (for small UPS products only) Feature Liebert IS-WEBCARD APC-MGE AP9619 Powerware ConnectUPS-E Tripp Lite SNMPCARD Enterprise Management System Compatible Yes Yes Yes Yes Fault notification Yes Yes Yes Yes Integrates with system shutdown software Yes Yes Yes Yes Password security Yes Yes Yes Yes Reboot equipment remotely Yes Yes Yes Yes Remote device management (software) Yes Yes Yes Yes SNMP Management Yes Yes Yes Yes
Servicing All Your Power And Related Equipment. Your investment in power and cooling equipment is worthless if you don’t maintain it. Not even the best equipment can function properly unless it’s serviced with a regular maintenance schedule. Emerson Network Power services the complete spectrum, from UPS to precision air systems to batteries and related power distribution equipment in your data center or in the other critical facilities where continuous availability of systems is essential.
Nobody Keeps Your Network Running Better. Peace-of-mind. It’s confidence you’ve done everything possible to assure system uptime. It’s confidence the critical support systems you rely on are operating at peak performance. It’s confidence you’ve selected the best partner available to bring you back online in the event of unexpected downtime.
Delivering Uptime Assurance. Emerson Network Power has the proprietary tools, industry knowledge and robust service infrastructure to deliver real assurance that your systems will be available when you need them. Our grid-to-chip maintenance strategy takes a system-focused approach to your critical equipment service, an approach that goes beyond standard offerings. It’s a comprehensive Service Solution that looks at the power and cooling needs of your entire enterprise.
You’ll Get A Response. And A Resolution. Unplanned downtime can occur any day, any time. Confident customers know their critical systems services partner will have them back and running quickly and efficiently. After all, if downtime should strike, you need a partner that can get you back online quickly with intelligent answers, rapid service response and parts where and when you need them. We Have The Resources Our Customer Resolution Center supports you 24x7x365.
The Company That Invented Critical Systems Protection. We invented the precision cooling system in 1965. We synchronized the first UPS load bus in 1991. We constructed the first enclosed protection system in 1994. And, in 2002, our innovation spawned the first high-density cooling system. For decades, Liebert technology has given IT organizations the reliability and flexibility they need to succeed.
Solutions Designed For Your World. Achieving mission-critical network availability requires the installation, management, and continuous support of your network’s infrastructure. This continuous availability rests on the power and cooling infrastructure that supports these systems, and requires four key components: 1. Mission Critical Power In addition, Liebert has created new power, cooling and monitoring solutions that help deliver continuous availability—and real value beyond the sum of the part.
Liebert Adaptive Architecture. The Liebert Adaptive Architecture is a combination of power, cooling and monitoring technologies that provide mission-critical IT support across your entire enterprise. The Liebert Adaptive Architecture delivers higher performance with greater flexibility than any other infrastructure design.
Ensuring The High Availability Of Mission-Critical Data And Applications. Emerson Network Power, the global leader in enabling business-critical continuity, ensures network resiliency and adaptability through a family of technologies — including Liebert power and cooling technologies — that protect and support business-critical systems. Liebert solutions employ an adaptive architecture that responds to changes in criticality, density and capacity.