User Manual

2929
Données techniques du CX1
Modèle
kW (Btu/
hr)
Tension
nominale
Groupe de gaz
Calibre de
câble d'aim.
***
Courant
nominal
Fusible de
circuit
Longueur du
boîtier
Code de
temperature
IIB +
H2
IIB IIC
Sans
t'stat
Avec
t'stat
Sans
t'stat
Avec
t'stat
V AWG A A po mm
CX1-400160-0125-T3 1.25 (4565) 400
+
12
3.1 15 31.3 796 T3 (200)
CX1-400160-018-T3 1.8 (6142) 400
12
4.5 15 31.3 796 T3 (200)
CX1-400160-025-T2A 2.5 (8530) 400
12
6.3 15 31.3 796 T2A (280)
CX1-400160-0333-T3 3.33 (11362) 400
12
8.3 15 49.5 1256 T3 (200)
CX1-400160-0347-T3 3.47 (11840) 400
12
8.7 15 71.8 1823 T3 (200)
CX1-400160-036-T3** 3.6 (12284) 400
12
9.0 15 49.5 1256 T3 (200)
CX1-400160-048-T2A 4.8 (16378) 400
10
12.0 15 49.5 1256 T2A (280)
CX1-400160-050-T3 5.0 (17060) 400
10
12.5 20 71.8 1823 T3 (200)
CX1-400160-0528-T2A 5.28 (18016) 400
10
13.2 20 59.5 1511 T2A (280)
CX1-400160-0694-T3 6.94 (23680) 400
N/A
8
17.4 25 71.8 1823 T3 (200)
CX1-400160-076-T2A 7.6 (25932) 400
N/A
8
19.0 30 59.5 1511 T2A (280)
CX1-400160-100-T2A 10.0 (34121) 400 N/A N/A
8
25.0 35 71.8 1823 T2A (280)
CX1-415160-009-T3 0.9 (3071) 415
12
2.2 15 31.3 796 T3 (200)
CX1-415160-012-T3 1.2 (4095) 415
12
2.9 15 31.3 796 T3 (200)
CX1-415160-0135-T3 1.35 (4606) 415
12
3.3 15 31.3 796 T3 (200)
CX1-415160-018-T3 1.8 (6142) 415
12
4.3 15 31.3 796 T3 (200)
CX1-415160-0269-T2A 2.69 (9179) 415
12
6.5 15 31.3 796 T2A (280)
CX1-415160-0359-T3 3.59 (12250) 415
12
8.7 15 49.5 1256 T3 (200)
CX1-415160-036-T3** 3.6 (12284) 415
12
8.7 15 49.5 1256 T3 (200)
CX1-415160-0374-T3 3.74 (12761) 415
12
9.0 15 71.8 1823 T3 (200)
CX1-415160-048-T2A 4.8 (16378) 415
10
11.6 15 4 9 .5 1256 T2A (280)
CX1-415160-050-T3 5.0 (17060) 415
10
12.0 15 71.8 1823 T3 (200)
CX1-415160-0568-T2A 5.68 (19381) 415
10
13.7 20 59.5 1511 T2A (280)
CX1-415160-0747-T2A 7.47 (25488) 415
N/A
8
18.0 25 71.8 1823 T2A (280)
CX1-415160-076-T2A 7.6 (25932) 415
N/A
8
18.3 25 59.5 1511 T2A (280)
CX1-415160-100-T2A 10.0 (34121) 415 N/A N/A
8
24.1 35 71.8 1823 T2A (280)
CX1-480160-012-T3 1.2 (4095) 480
12
2.5 15 31.3 796 T3 (200)
CX1-480160-018-T3 1.8 (6142) 480
12
3.8 15 31.3 796 T3 (200)
CX1-480160-036-T3** 3.6 (12284) 480
12
7.5 15 49.5 1256 T3 (200)
CX1-480160-048-T2A 4.8 (16378) 480
12
10.0 15 49.5 1256 T2A (280)
CX1-480160-050-T3 5.0 (17060) 480
12
10.4 15 71.8 1823 T3 (200)
CX1-480160-076-T2A 7.6 (25932) 480
N/A
10
15.8 20 59.5 1511 T2A (280)
CX1-480160-100-T2A 10.0 (34121) 480
N/A
8
20.8 30 71.8 1823 T2A (280)
CX1-600160-012-T3 1.2 (4095) 600 N/A
12
2.0 15 31.3 796 T3 (200)
CX1-600160-018-T3 1.8 (6142) 600 N/A
12
3.0 15 31.3 796 T3 (200)
CX1-600160-036-T3** 3.6 (12284) 600 N/A
12
6.0 15 49.5 1256 T3 (200)
CX1-600160-048-T2A 4.8 (16378) 600 N/A
12
8.0 15 49.5 1256 T2A (280)
CX1-600160-050-T3 5.0 (17060) 600 N/A
12
8.3 15 71.8 1823 T3 (200)
CX1-600160-076-T2A 7.6 (25932) 600 N/A
12
12.7 20 59.5 1511 T2A (280)
CX1-600160-100-T2A 10.0 (34121) 600 N/A N/A
10
16.7 25 71.8 1823 T2A (280)
4. 
ambiante. Option haute température de stockage n'est pas disponible avec
l'option thermostat. Non disponible sur les modèles IIB.
5. Pour le modèle IIB avec Defender
®
thermostat intégré - Classe I, Div. 1 & 2,
Groupes C et D; Zones 1 & 2, Groupes IIA et IIB.
6. Pour IIC modèle XT avec thermostat intégré - Classe I, Div. 1 & 2, Groupes A,
B, C et D; Zones 1 & 2, Groupes IIA, IIB et IIC.
7. Regroupement des unités de la SII sont livrés avec x-Max
®
logement.
8. Monté à distance, Defender, thermostats d'ambiance anti-explosion ne
sont pas adaptés pour le Groupe B & IIC applications.
9. Contacteurs à distance sont nécessaires sur tous les chauffe-600V et
appareils de chauffage avec un appel de courant supérieur à 22 ampères
(fournie et installée par d'autres), lors de l'utilisation XT-311
thermostat à distance.
10. 
(200°C) .