1-Phase CX1 Technical Data
Model
kW (Btu/
hr)
Unit
Voltage
Gas Group
Supply
Wire Size ***
Unit
Current
Max. Circuit
Fuse*
Cabinet
Length
Temperature
Code
IIB +
H2
IIB IIC
V
w/o
T'stat
w/
T'stat
w/o
T'stat
w/
T'stat
AWG A A
in (mm)
CX1-400160-0125-T3 1.25 (4565) 400
12 3.1 15 31.3 (796) T3 (200)
CX1-400160-018-T3 1.8 (6142) 400
12 4.5 15 31.3 (796) T3 (200)
CX1-400160-025-T2A
2.5 (8530)
400
12
6.3
15
31.3 (796)
T2A (280)
CX1-400160-0333-T3 3.33 (11362) 400
12 8.3 15 49.5 (1256) T3 (200)
CX1-400160-0347-T3 3.47 (11840) 400
12 8.7 15 71.8 (1823) T3 (200)
CX1-400160-036-T3** 3.6 (12284) 400
12 9.0 15 49.5 (1256) T3 (200)
CX1-400160-048-T2A
4.8 (16378)
400
10
12.0
15
49.5 (1256)
T2A (280)
CX1-400160-050-T3 5.0 (17060) 400
10 12.5 20 71.8 (1823) T3 (200)
CX1-400160-0528-T2A 5.28 (18016) 400
10 13.2 20 59.5 (1511) T2A (280)
CX1-400160-0694-T3 6.94 (23680) 400
N/A 8 17.4 25 71.8 (1823) T3 (200)
CX1-400160-076-T2A 7.6 (25932) 400
N/A 8 19.0 30 59.5 (1511) T2A (280)
CX1-400160-100-T2A 10.0 (34121) 400 N/A N/A 8 25.0 35 71.8 (1823) T2A (280)
CX1-415160-009-T3 0.9 (3071) 415
12 2.2 15 31.3 (796) T3 (200)
CX1-415160-012-T3 1.2 (4095) 415
12 2.9 15 31.3 (796) T3 (200)
CX1-415160-0135-T3 1.35 (4606) 415
12 3.3 15 31.3 (796) T3 (200)
CX1-415160-018-T3 1.8 (6142) 415
12 4.3 15 31.3 (796) T3 (200)
CX1-415160-0269-T2A 2.69 (9179) 415
12 6.5 15 31.3 (796) T2A (280)
CX1-415160-0359-T3 3.59 (12250) 415
12 8.7 15 49.5 (1256) T3 (200)
CX1-415160-036-T3** 3.6 (12284) 415
12 8.7 15 49.5 (1256) T3 (200)
CX1-415160-0374-T3 3.74 (12761) 415
12 9.0 15 71.8 (1823) T3 (200)
CX1-415160-048-T2A 4.8 (16378) 415
10 11.6 15 49.5 (1256) T2A (280)
CX1-415160-050-T3 5.0 (17060) 415
10 12.0 15 71.8 (1823) T3 (200)
CX1-415160-0568-T2A 5.68 (19381) 415
10 13.7 20 59.5 (1511) T2A (280)
CX1-415160-0747-T2A 7.47 (25488) 415
N/A 8 18.0 25 71.8 (1823) T2A (280)
CX1-415160-076-T2A 7.6 (25932) 415
N/A 8 18.3 25 59.5 (1511) T2A (280)
CX1-415160-100-T2A 10.0 (34121) 415 N/A N/A 8 24.1 35 71.8 (1823) T2A (280)
CX1-480160-012-T3 1.2 (4095) 480
12 2.5 15 31.3 (796) T3 (200)
CX1-480160-018-T3 1.8 (6142) 480
12 3.8 15 31.3 (796) T3 (200)
CX1-480160-036-T3** 3.6 (12284) 480
12 7.5 15 49.5 (1256) T3 (200)
CX1-480160-048-T2A 4.8 (16378) 480
12 10.0 15 49.5 (1256) T2A (280)
CX1-480160-050-T3 5.0 (17060) 480
12 10.4 15 71.8 (1823) T3 (200)
CX1-480160-076-T2A 7.6 (25932) 480
N/A 10 15.8 20 59.5 (1511) T2A (280)
CX1-480160-100-T2A 10.0 (34121) 480
N/A 8 20.8 30 71.8 (1823) T2A (280)
CX1-600160-012-T3 1.2 (4095) 600 N/A
12 2.0 15 31.3 (796) T3 (200)
CX1-600160-018-T3 1.8 (6142) 600 N/A
12 3.0 15 31.3 (796) T3 (200)
CX1-600160-036-T3**
3.6 (12284)
600
N/A
12
6.0
15
49.5 (1256)
T3 (200)
CX1-600160-048-T2A 4.8 (16378) 600 N/A
12 8.0 15 49.5 (1256) T2A (280)
CX1-600160-050-T3 5.0 (17060) 600 N/A
12 8.3 15 71.8 (1823) T3 (200)
CX1-600160-076-T2A 7.6 (25932) 600 N/A
12 12.7 20 59.5 (1511) T2A (280)
CX1-600160-100-T2A 10.0 (34121) 600 N/A N/A 10 16.7 25 71.8 (1823) T2A (280)
5. Add suffix "H" for high-temperature ambient storage option. High
temperature storage option is not available with thermostat option.
Not available on IIB models.
6. For IIB model with Defender® built-in thermostat - Class I, Div. 1 & 2,
Groups C & D; Zones 1 & 2, Groups IIA and IIB.
7. For IIC model with XT built-in thermostat - Class I, Div. 1 & 2, Groups
A,B,C & D; Zones 1 & 2, Groups IIA, IIB, IIC.
8. IIC Grouping units come with x-Max® housing.
9. Remote mounted, Defender, explosion-proof room thermostats are
not suitable for Group B & IIC applications.
10. Remote contactors are required on all 600V heaters, and heaters with
a current draw greater than 22 amps (supplied & installed by others),
when utilizing XT-311 remote thermostat.
11. Temperature code ratings: T2A - 280°C (536°F), T3 - 200°C (392°F)