User guide

18
Introducing the ZoneFlex Access Point
Getting to Know the Access Point Features
LED Colors and What They Mean
Refer to Table 13 below for a list of LED states and what they indicate.
3 Reset Using a pointed object (for example, a pen), press this
button to restart the Access Point or to restore it to
factory default settings:
To restart the Access Point, press the Reset button
once.
To restore the Access Point to factory defaults, press
and hold the Reset button for six (6) seconds.
WARNING: Restoring the Access Point to factory default
settings removes all configuration changes that you have
made. These include the IP address, password, access
control list, and wireless settings. Returning the
configuration of these features to their factory default
settings may result in network connectivity issues.
4 12V DC In addition to PoE, you can also use direct current or DC
(from a battery, for example) to supply power to the
Access Point.
Table 13. ZoneFlex 2741 LED states and behaviors
LED Meaning
OPT Not used in this model
DIR
Off: The AP is not being managed by ZoneDirector
(standalone mode).
Green: The AP is being managed by ZoneDirector.
Slow flashing green (one flash every two seconds):
The AP is being managed by ZoneDirector, but is
currently unable to communicate with
ZoneDirector.
Fast flashing green (two flashes every second): The
AP is being managed by ZoneDirector and is
currently receiving configuration settings
(provisioning) or a firmware update.
Table 12. ZoneFlex 2741 LEDs and bottom panel connectors
No Label Description