Operation Manual
20. Please keep the replace and wiring dry when transporting or storing them (remove the water
before moving the replace). Avoid strenuous vibration to prevent damage to the replace.
21. In order to avoid overheating, do not cover the heater.
22. The heater must not be located immediately below a socket-outlet.
23. When you are not using the unit for a longer period of time or if you want to transport please
empty the container.
INSTALLATION
This section is the guidance for electric replace installation
Leave a clearance of at least 1cm between the replace recess and the surround of the replace to
ease installation.
The electric replace does not need a ue.
Warning
1. The power socket shall be AC230V/15A three-core socket with excellent earth, fuse and earth
leakage protection.
2. Note:
In order to avoid overheating, do not cover the heater. Do not scrape the plastic off the core of
replace or install the core directly on a soft surface. Otherwise, it may block the air circulation and
cause re accidents.
Install the electric replace in dry and safe places free from dust and ammable articles. Please
ensure that objects such as curtains not to block the outlet.
3. It is possible that the ames become lower when the heating function is switched on. This can be
prevented by placing the surround 10 mm from the wall.
Reminder
1. It is advisable to install the electric replace near the socket to ease electric installation.
2. First place the electric replace on the selected position to see whether it is satisfactory.
3. This electric replace is not allowed to be installed directly onto a wall. Place the mantel in the
desired location or build a replace recess in the desired location on the oor near the wall. The
size of the recess should be:
Model
Specication of The Opening
W H D
MF1530H 45.0cm 66.0cm 26.0cm
MF1510H 63.5cm 68.5cm 26.0cm
When placing the replace or building the wall structure, please place the insert in dry, safe
and clean place.
4