System Guide

SME VOIP SYSTEM GUIDE 4.7 76 | P a g e
Proprietary and Confidential
PARAMETERS
DESCRIPTION
IDX/NAME
Base IP address and base station name from management settings
OPERATION
D-H:M:S
Total operation time for the repeater since last reboot or reset
Duration is the time from data was cleared or system has been firmware upgraded.
BUSY
Busy Count is the number of times the repeater has been busy.
BUSY DURATION
D-H:M:S
Busy duration is the total time a repeater has been busy for speech (5 or more calls
active).
MAX ACTIVE
Maximum active calls are the maximum number of calls that have been active at the
same time.
SEARCHING
Repeater searching is the number of times a repeater has been searching for its sync
source
RECOVERY
In case the sync source is not present anymore the repeater will go into lock on another
base or repeater and show recovery mode
DECT SOURCE
CHANGED
Number of times a repeater has changed sync source
WIDE BAND
Number of wideband calls on repeaters
NARROW BAND
Number of narrowband calls on repeaters
5.16.5 DECT data
The DECT data web is accessed by http://ip/DectStatistics.html and data is organized in a table as shown in below
example.
Screenshot
PARAMETERS
DESCRIPTION
FREQUENCY
Number of the DECT slot frequency
SLOTX
Number of connections that have been active on each frequency