System Guide
SME VOIP SYSTEM GUIDE 4.7 71 | P a g e
Proprietary and Confidential
Call: An outgoing call to the specified emergency
number.
Beacon message: Sends a beacon to the alarm
server which sends a message to the handset
STOP ALARM
FROM HANDSET
Enabled
Enable/Disable the possibility to stop/cancel the
alarm from the handset.
TRIGGER DELAY
0
The period from when the alarm has fired until the
handset shows a pre-alarm warning. If set to 0,
there will be no pre-alarm warning, and the alarm
will be signaled immediately. The alarm algorithm
typically needs about 6 sec. to detect e.g. man
down etc.
STOP PRE-
ALARM FROM
HANDSET
Enabled
Enable/Disable the possibility to stop/cancel the
pre-alarm from the handset.
PRE-ALARM
DELAY
0
The period from the pre-alarm warning is shown
until the actual alarm is signaled. The maximum
value is 255.
HOWLING
Disabled
Enable/Disable if howling shall be started in the
handset, when the alarm is signaled. If disabled,
only the configured signal is sent (call or message).
NOTE: The alarm feature is only available on some types of handsets (e.g. RTX8632, RTX8633 and RTX8830)
After configuration, the handset must be rebooted.