System Guide
SME VOIP SYSTEM GUIDE 4.7 69 | P a g e
Proprietary and Confidential
The number of repeaters allowed on each base station is mentioned above in 5.14.1.1.
System combination: 50/3 – 127/1 -254/0.
If the system combination is set to 127/1 or 254/0 you can still register more than one repeater, but it will not get a
DECT Sync source and have no function.
Example:
System combination 50/3:
Base stations are named RPN00 – RPN04 – RPN08. Etc. jumping 4 numbers each time (HEX numbers)
Repeaters connect to base station RPN00 will be called RPN01 – RPN02 – RPN03 (HEX numbers)
Repeaters connect to base station RPN04 will be called RPN05 – RPN06 – RPN07 (HEX numbers)
Etc.
System combination 127/1:
Base stations are named RPN00 – RPN02 – RPN04. Etc. jumping 2 numbers each time (HEX numbers)
Repeaters connect to base station RPN00 will be called RPN01 (HEX numbers)
Repeaters connect to base station RPN02 will be called RPN05 (HEX numbers)
Etc.
System combination 254/0:
Repeater registration not possible.
PARAMETERS
DESCRIPTION
IDX
Repeater unit identity in the chained network.
Permitted Output: Positive Integers
RPN
The Radio Fixed Part Number is an 8-bit DECT cell identity allocated by the installer. The
allocated RPN within the SME must be geographically unique.
Permitted Output: 0 to 255 (DEC) OR 0x00 to 0xFF (HEX)
NAME/IPEI
Contains the name and the unique DECT serial number of the repeater. If name is not
given the field will be empty.
DECT SYNC
SOURCE
The “dual cell chain” connection to the specific Base/repeater unit. Maximum number of
chain levels is 12.
Sync. source format: “RPNyy (-zz dBm)”
yy: RPN of source
zz: RSSI level seen from the actual repeater
DECT SYNC MODE
Manually: User controlled by manually assign “Repeater RPN” and “DECT sync source
RPN”
Local Automatical: Repeater controlled by auto detects best base signal and auto assign
RPN.
Chaining Automatical: Base controlled by auto detects best base or repeater signal and
auto assign RPN. This feature will be supported in a future version
STATE
Present@unit means connected to unit with RPN yy
FW INFO
Firmware version
FWU PROGRESS
Possible FWU progress states:
Off: Means sw version is specified to 0 = fwu is off
Initializing: Means FWU is starting and progress is 0%.
X% : FWU ongoing
Verifying X%: FWU writing is done and now verifying before swap
”Conn. term. wait” (Repeater): All FWU is complete and is now waiting for connections
to stop before repeater restart.
Complete HS/repeater: FWU complete
Error: Not able to fwu e.g. file not found, file not valid etc.