System Guide

SME VOIP SYSTEM GUIDE 4.7 67 | P a g e
Proprietary and Confidential
PARAMETERS
DEFAULT VALUES
DESCRIPTION
NAME
Empty
Repeater name. If no name specified, the field will be empty
DECT SYNC
MODE
Local Automatical
Manually: User controlled by manually assign “Repeater RPN” and
“DECT sync source RPN”
Local Automatical: Repeater controlled by auto detects best base
signal and auto assign RPN.
5.14.1.1 Manually
If the mode is chosen to be “Manually”, the assigned parameters “Repeater RPN” and “DECT sync source RPN” must
be selected by the drop-down menu.
Screenshot
After saving the configurations above, the repeater will be visible on the main “Repeaters” menu with the following
parameters:
Screenshot
PARAMETERS
DESCRIPTION
IDX
System counter
RPN
SINGLE CELL SYSTEM:
The base has always RPN00, first repeater will then be RPN01, second repeater RPN02
and third RPN03 (3 repeaters maximum per base)
DUAL CELL SYSTEM:
Bases are increment by 2^2 in hex, means first base RPN00 second base RPN04 etc., in
between RPN01, 02, 03 addressed for repeaters at Primary base and 05, 06, 07 addressed
for Secondary base (3 repeaters maximum per base)
NAME/IPEI
Name and IPEI number of the repeater
DECT SYNC MODE
DECT Sync mode Manually or Automatic
STATE
State of the repeater Enabled/Disabled
FW INFO
Firmware version
FWU PROGRESS
How many percentages of the firmware is loaded / Off if no firmware is being loaded